MODELS • 804702 • 805087
MODEL 804702 INSTALLATION
For use with Wolf 48"–66" wide x 18" tall Wall
Hoods.
Slide TAB on ventilator top plate through RECTANGULAR SLOT
on underside of VENTILATOR MOUNTING PLATE (provided).
Secure VENTILATOR to ventilator mounting plate by attaching
1/4-20 HEX NUT (provided) to THREADED STUD on ventilator
mounting plate.
Use eight (8) HEX NUTS (provided) to attach ventilator mounting
plate assembly to eight (8) THREADED STUDS on hood top
plate.
Plug ventilator's POWER CORD into RECEPTACLE inside the
hood. Route ventilator's power cord away from moving parts.
MODEL 805087 INSTALLATION
For use with Wolf 34"–58" wide x 12" tall Liner
Hoods.
Slide TAB on ventilator top plate through RECTANGULAR SLOT
on underside of VENTILATOR MOUNTING PLATE.
Secure VENTILATOR to ventilator mounting plate by attaching
1/4-20 HEX NUT (provided) to THREADED STUD on ventilator
mounting plate.
Plug ventilator's POWER CORD into RECEPTACLE inside the
hood. Route ventilator's power cord away from moving parts.
HEX
NUTS (8)
THREADED STUDS (8)
VENTILATOR
MOUNTING
PLATE
VENTILATOR
THREADED
STUD
1/4-20 HEX NUT
VENTILATOR
MOUNTING
PLATE
VENTILATOR
THREADED
STUD
RECTANGULAR
SLOT
TAB
POWER CORD
RECEPTACLE
1/4-20 HEX NUT
TAB
RECTANGULAR SLOT
POWER CORD
RECEPTACLE