wolfappliance.com
|
5
WARNING
The complete appliance must be properly grounded at
all times when electrical power is applied.
Do not ground appliance with the neutral (white) house
supply wire. A separate ground wire must be utilized.
If aluminum house supply wiring is utilized, splice the
appliance copper wire to the aluminum house wiring
using special connectors design and agency certified
for joining copper and aluminum. Follow the connector
manufacturer's recommended procedure carefully.
Improper connection can result in a fire hazard.
SPECIFICATIONS
Induction cooktop.
Electric cooktop.
RATING PLATE
RATING PLATE
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Performance may be compromised if the electrical supply is
less than 240 volts.
When multiple cooktops are installed side by side, each unit
must have its own separate recommended electrical circuit.
ELECTRICAL REQUIREMENTS
INDUCTION / ELECTRIC
Electrical Supply
3-wire, 240/208 VAC, 60 Hz
Conduit
flexible 4'
(1.2 m)
SERVICE
15" Induction / Electric
20 amp dedicated circuit
24" Induction
30 amp dedicated circuit
30" Induction / Electric
40 amp dedicated circuit
36" Induction / Electric
50 amp dedicated circuit