FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
F32700 (February 2006)
Page 23 of 64
BLOWER ADJUSTMENT
WARNING:
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
WARNING:
SHUT OFF THE GAS BEFORE SERVICING THE UNIT.
1.
Remove the blower motor and mounting assembly by following steps 1 through 8 as outlined under BLOWER
AND MOTOR in REMOVAL AND REPLACEMENT OF PARTS.
2.
Loosen the motor mounting bolts.
3.
Adjust the motor position until the blower is parallel to and 1/4 inch away from the motor mounting plate.
Check for squareness of the blower to the motor mounting plate at the top, bottom, left and right of the
blower.
A.
If the blower is square then tighten motor mounting bolts and proceed to step 4.
B.
If the blower is not square continue adjusting until proper spacing is achieved then tighten motor
mounting bolts.
NOTE:
If necessary, place shims between motor and frame.
4.
Reverse the procedure to install.