Wolf 00332 User Manual Download Page 8

3.

Personal

Safety

4-

Be

attentive,

concentrate

on

the

job

and

use

common

sense

when

working

with

pillar

drills. Do

not

operate

the

pillar

drill

when

you

are

tired

or

under

the

influence

of

drugs.

alcohol

or

medication

A

moment

of carelessness

when

using

the

pillar

drill

can

lead

to

serious

injury.

Wear CE

approved personal protective

equipment. Wearing

CE

approved personal

protective equipment

appropriate

to the

type

of

pillar

drill

and the

application (such

as

a

dust

mask,

non»slip

footwear,

a

safety

helmet,

safety

goggles

or

ear

protection),

reduces

the

risk of

injury.

Avoid

unintentionally starting

the

pillar

drill. Ensure

that the

power

switch is

in the

'OFF‘

position

before

connecting

the

pillar

drill

to

the mains.

Carrying

the

pillar

drill with your

finger

on

the

trigger

or

connecting

the

pillar

drill

to

mains

when

switched

on

can

lead

to

accidents.

Remove

any

adjusting

tools

or

keys

before

turning

the

pillar

drill

on.

A tool

or

key

connected

to

a

rotating part

of the

pillar

drill

can

lead

to

injuries.

Do

not

over-reach.

Maintain

a

stable

posture

and

keep

your

balance.

This

can

improve

your control

over

the

pillar

drill in

unexpected

situations.

Wear

appropriate clothing.

Do

not

wear

loose

fitting

clothes

or

jewellery. Keep

hair,

clothing,

and

gloves

away

from

moving

parts.

Loose

fitting

clothes,

jewellery

or

long

hair

can

be

caught

up

in

moving parts.

If

dust extraction

or

collection

devices

can

be

fitted,

ensure

these

are

connected

and

correctly operated. Using

these

devices

reduces

the

danger posed by

dust.

Correct

handling

and

operation

of

pillar

drills

Do

not

overload

the

pillar

drill. Use

the

appropriate

pillar

drill for

the

job.

You

can

work

more

safely

and

effectively

using

the

appropriate pillar

drill within the

range

of its

capacity.

Do

not

use

pillar

drills with defective

power

switches.

A

pillar

drill which

can

no

longer

be

switched

on

and

off

is

dangerous

and

must

be

repaired.

Disconnect

the

pillar

drill

from the

mains

before

carrying

out

adjustments, changing pillar

drill

or

accessories

and

putting

the

pillar

drill away.

This

precautionary

measure

prevents

unintentional

starting.

Store

pillar

drills

out of

the reach

of children

when

not

in

use.

Do not

allow

people

who

are

unfamiliar

with

the

pillar

drill

or

have

not

read these

instructions

to

use

the

pillar

drill.

Maintain

the

pillar

drill with

care,

Ensure

the

moving

parts

function

correctly

and

do not stick.

Check

whether

parts

are

broken

or

are

so

badly damaged

that

the

pillar

drill’s

functions

are

impaired.

Have

damaged

parts

repaired

before

operating

the

pillar

drill.

Many

accidents

are

caused

by badly

maintained

pillar

drills.

Wolf-106302

Page

8

All manuals and user guides at all-guides.com

Summary of Contents for 00332

Page 1: ...MP 98 ce 2 7_ USER MANUAL TECHNICAL SUPPORT 0330 123 0001 ynur own safely Ian g y A opmnng manual Nanny before opera ng Hus praduct All manuals and user guides at all guides com a l l g u i d e s c o...

Page 2: ...6 Ben Tension Bali 7 Securing Boh __ a Base 9 Column 0 On OH Bu on Haadsmk 12 Grub Screw Ia ChuckGuan J 14 Chuck 15 Work Table _4__ Wolf 106302 Page 2 All manuals and user guides at all guides com...

Page 3: ...hlighted throughout this manual Vou are extremes Important and should be e read un rstood and implemented advrsed to read and follow the instructions given before anemp ng to use your Examples of what...

Page 4: ...hase when sending in your product for repair After the warranty has expired you can still send defective pillardrills for repairs FREIGHT PREPAlD to the address on the right of this page Quotes as wel...

Page 5: ...Speci cation l H I All manuals and user guides at all guides com...

Page 6: ...dnll the purpose of wamrng symbolsrs lo make you aware of possible hazardous condillons Remember Ihal safety messages do not alrmrnale dangerand are not a subsmute for proper accrdenr prevenuon measur...

Page 7: ...aptors with earthed equipment Unmodi ed plugs and appropriate sockets reduce the risk of electric shock Never pull the cable to unplug the pillar drill keep the cable from heat oil and sharp edges Avo...

Page 8: ...thing and gloves away from moving parts Loose ttingclothes jewellery or long hair can be caught up in moving parts If dust extraction or collection devices can be tted ensure these are connected and c...

Page 9: ...ccessories that may be suitable for one pillardrill may become hazardous when used on another pillardrill Service i Pillar drill servicingmust be performed by a quali ed repair person Sen ice or maint...

Page 10: ...void drillinginto the able Shut off the power remove the drill bit and clean the table before leaving pillardrill Do not connect tool to power source or operate until it is completely assembled and in...

Page 11: ...ure to line and or extension with conductor of at least 1 5mm2 follow these warning could result in serious injuries and protected with a 13A fuse Be sure that this extension 2 This pillar drill must...

Page 12: ...remove all parts and lay them on a flat stable surface Remove all packaging and shipping materials Do not discard the packing materials save should the pillar drill need to be repaired in the future...

Page 13: ...the ar drill onto the column as a as it will go Unscrew the i an screws in the headstock rig to avoid obstructing internal diameter ol headstock Align the stock horizontally to the able and base Secur...

Page 14: ...l is switched off the pillar drill will not restart without warning when the mains power has been restored or the mains power has been re connected To start the pillar drill press the green ON button...

Page 15: ...en the belt tension locking bolt This damage to the gillard lt will allow the tension on the drive belt to be released The motor assembly is hinged to allow Belt tension tensioning of the drive belt T...

Page 16: ...Observe the technical requirements of this product when purchasing drill bits Drill bits become hot during use Drill bits are very sharp Handle drill bits carefully Wear CE approved safety gloves when...

Page 17: ...d and vice tighteningthe chuck with the key verse 4 Turn the chuck key clockwise to tighten and counterclockwise to loosen the chuck jaws 5 Tightenall three chuck jaws to secure the drill bit sufficie...

Page 18: ...t properlyfor material Needs lubrication Feed pressure wrong Needs lubrication Table lock tightened Volf lO 302 Page 18 Solution 99 or were 9 9 F 999 a b Adjust tension Remove splndlelquillassembly an...

Page 19: ...d coolant or any kind of continuous coolant pump Remove all swan and dust after each operation Spread oil onto unplated sun aces especially if the pillar drill is not used for long periods Lubricate t...

Page 20: ...ctromagnetic Directive WARNING While your Walt Pillar Drill has been designed and manufactured according to the above safety standards you are reminded the incorrect use at your Wolf Pillar Drill may...

Reviews: