Wolf-Guard YL-007Z Manual Download Page 7

infomation. 

12. Setting Up User’s Code 
   Press holding the key

Code

for 3 sec., key in 4-digit user’s code when figure 

bar cursor twinkling on panel screen. The code will be transmitted to alarm 
center to identify the users. If your system has not connected with the center 
yet, it is no necessary for you to set up user code. 

13. System Initialization 

Press the key

program

on the panel under the disarming status, then press

【▲】

and

【↓】

to twinkle typeface “ Other Setup” , press

【#】

to confirm , press 

【▲】

and

【↓】

 to make “system initialization” twinkle, pressing

【#】

to 

comfirm entering system initialization status. All the set will be recovered to 
original status.( Those code of P.I.R , door magnet, remote controller, 
intelligent remote control switch will lose and must be renwed code) 

 

System Usage   

 

1.

 

Arm/ Disarm 

¾

 

Keyboard Arming/ Disarming 

Key in 4-digit password on keyboard under disarming status, press the key 

【Out】

going to away disarming status, press the key 

【Home】

going to stay 

disarming status. Key in 4-digit password on keyboard under arming or alarm 
status, press 

【*】

to disarm. Current status will display on the screen at the 

same time. 
Notice: All the defence zones will take effect under

Out

  status , the mode is 

suitable for nobody-in. Part of    the defence zones take effect under

Home

 

status , the mode is suitable for anybody-in. 

¾

 

Remote Controller Arming/ Disarming 

Press the key

Lock

on the remote controller, the system will enter away 

disarming status about 20-60 sec. delay later. By use the key

Lock

 

together with

Urgency

on the remote controller, you can arm at once

.  

Main panel will send off indicating tone to denote that phone line are not 
ready.  Press the key

Unlock

on the remote controller to disarm. 

2.

 

Panic Alarm 
Press the middle key 

Urgency

on the remote controller or on the panel , the 

system will alarm at once and dial automatically whether it is in arming status 
or not.   
 

3.

 

Dealing With Alarm   
The system will make horn hoot for 5 minutes to frighten intruder, while it also 
dials the saved phone numbers automatically. Hosts will hear the saved alarm 
message when they pick up the telephone. Press the

【*】

  to enter 2 minutes of 

spot monitoring status, press

【#】

to confirm receiving alarm. The main panel will 

stop dial and close horn. The system will arm again. If one number can’t be put 

Summary of Contents for YL-007Z

Page 1: ...red sharp light proof detector brings you more safety Superior program could satisfy various individuation requirements All the arming disarming and alarm memory will be recorded The safety bugs can be inspected in time by the tech of detector self inspection in system Your convenient life comes true once the home appliances are in long distance control by telephone Please read the manual carefull...

Page 2: ...iance by telephone Long distance arming disarming by telephone and monitoring the sound on spot Could saving 40 arming disarming and alarm records including time defence zone and detector location etc With the patent tech of detector self inspection the panel will lighten the fault indicator light to show the right location and remind of user if it hasn t received the signal from detector within 2...

Page 3: ...one History Inquiring about info of arming disarming alarm time and defense zone Page Up and Page Down Code For coding detector remote controller and intelligent remote control switch together with setting up user s code Defense Zone Setup For entry into defense zone setup mode Programme For entry into programme mode Arming Away To start up arming away mode Arming Stay To start up arming stay mode...

Page 4: ...rect light irradiation whenever in the day or night Also it should be kept away from air conditioner and stove etc Its installation height is suggested within 2 to 2 2 meters and its detection angle should be adjusted face to detector zone directly P I R goes to work after 1 minute warm up once turning on the power supply switch notice installation position will cause the alarm veracity 4 Intellig...

Page 5: ...rd press to confirm entering code status you can key in your code when the figure bar cursor twinkling on the foot of the screen pressing to comfirm It s a 4 digit number please remember it the original password is 1234 4 Settingup Horn The alarm system could decide to use horn or not just up to your demand Press the key program on the panel under the disarming status then press and to twinkle typ...

Page 6: ...e detector is not suited Every defence zone could accept several detectors Attached detectors have been coded before selling door magnets have been set as the first defense zone stay defence no delay hall The P I R is regarded as the second defence zone out defence zone no delay bedroom 9 Remote Controller Code Press the key program on the panel under the disarming status then press and to twinkle...

Page 7: ...press to disarm Current status will display on the screen at the same time Notice All the defence zones will take effect under Out status the mode is suitable for nobody in Part of the defence zones take effect under Home status the mode is suitable for anybody in Remote Controller Arming Disarming Press the key Lock on the remote controller the system will enter away disarming status about 20 60 ...

Page 8: ...umber and serial number 1 4 correspond 1 4 remote control switch The intelligent remote control switch will change its status between turning on and turning off You should hang up and go into remote control system again if you want to change its status Intelligent remote control switch panel itself could operates switch by manual work System Main Tech Parameter Main Panel Power Supply AC 220V 10 D...

Page 9: ...stance 5 8m Detective View Level 110 Vertical 60 Anti Puppy Jamming Rodent animal bulk Φ30 50mm Sharp White light Resistence 20000Lux Working Envrionment Temperature 10 40 Relative Humidity 90 Remote Controller Power Supply DC 12V 8 4 Inside A23 DC 12V dry battery Static Current 11 0 Emission Current 12 15 mA Emission Frequency f 315 0 2 MHz Emission Time T 1 second Emission Distance Without obstr...

Page 10: ... Standard pile layer 6 Transpotation Condition Standard pile layer 6 Avoid impact during transit other condition are as above After Service We supply user with perfect after service Don t tear open and maintain by yourselves if it doesn t work please contact your local seller Regarding details please refer to attached Guarantee Card ...

Reviews: