2.3 Digital Metric Marking
The cable reel has a digital metric marking integrated, so that the position of
the defect can be exactly determined during the inspection and a distance
measurement in the pipe will be possible. The green LED shows that the metric
marking is ready for operation. The LED will shine as soon as the camera head is
switched on. The result of the meter measurement will be shown in the monitor. If
necessary, you will have to configurate the display menu correspondingly.
A special button can reset the metric marking to zero in every position, for
example at the chimney entry. The way of the camera until the entry of the
chimney will not be included in the measurement and the exact position of the
defect in the pipe will be shown. For measuring the distance, reset the metric
marking to zero at the initial point (by pressing the operation button for two
seconds) and then read off the distance at the end point.
3. Changing the cable
For changing the cable, first release the brake. Then pull the cable carefully out
of the reel. Now disconnect the connection between cable and cable reel and
take out the cable.
Then carefully turn the cable reel clockwise almost one rotation back up to the
stop position. Guide the jack of the new cable through the loop to the clutch
socket and connect them. Now you can roll up the viper anticlockwise. While
rolling up the cable, pay attention that it coils smooth around the reel.
Fix the brake as described in point 2.2.3.
If you insert a cable with another length, you will have to change the parame-
ters. Press the operation button during about three seconds for switching on the
monitor. The parameters will be shown in the first line. With a double-click on the
operating button of the cable reel the blinking cursor can be moved to the right.
Clicking once the counter can be changed. By pressing the button for three se-
conds, the value will be stored. After that the new parameters will be displayed.
The parameters must be entered according to the following table: