Page 88
Address and IP Mask. At this time, the Gateway and DNS settings are not
used.
Also, the center navigation button will change its text from Cancel to Save/Exit
depending on whether the IP Address and IP Mask settings are usable.
4.
Adjust: Pressing this knob advances the highlight to the octet to the right.
Rotating this knob increases or decreases the octet number from 0 to 255.
Hardware Configuration Menu
The menu allows you to select a clock source and set reference levels. It also
provides a link to the Unit Information Menu.
Note:
Except for the Clock Source, these settings are not stored or recalled as
part of a preset. The Clock Source is saved as part of each preset.
Configuration Selection
Menu
Main Screen
Menu
Configure
Options
Option
Configuration Menu
Hardware
Configuration Menu
Configure
Hardware
Figure 5–16: Hardware Configuration Menu
Hardware Configuration Menu
Save / Exit
Help
Cancel
Unit
Info
Factory
Default
-20dBFS = +4 dBu
Analog I/O
Ref Level
Current: Internal Sync
Clock
Source
Selected Slot 4 (AES In) Pair 1
8 hours
Screen
Saver
Screen
Bright
Balance
Control
Menu Lock
SuperPair
Balance
Left
Right
16
32
1.
Clock Source: Rotating this knob selects the input source for audio clocking.
You can use the Ref input on the rear panel to provide a Genlock sync signal
to which all sources are locked. To use this connector, set this control to Ref
Genlocked. If there is only one input card and no Ref input, this is