![Wohler AMP1-VSD User Manual Download Page 19](http://html.mh-extra.com/html/wohler/amp1-vsd/amp1-vsd_user-manual_991564019.webp)
© 2004 Wohler Technologies Inc. ALL rights reserved
19
AMP1-VSD
User Manual P/N
821615
, Rev-
A
Section 3:
Technical Information
Description
The
919050 Digi-2
(
Dual Input AES to Analog Converter
) module allows selected Wohler Technologies products to receive
input signals in the
AES
or
SPDIF
digital audio data formats. Sampling rate and format selection are sensed and set automatically.
Two front panel mounted bi-color (RED/GREEN) LEDs provide visual indication of input signal status. The LEDs light GREEN
when receiving a valid, error-free data stream, but turn RED when errors are detected. See
Item 11
, page
10
for more information
about error detection and indication.
There are two
AES
inputs, which can be configured with unbalanced 75
Ω
BNC connectors and/or balanced 110
Ω
XLR
connectors. This module also features a four-channel balanced
Analog
line-level output, which can be configured with unbalanced
75
Ω
BNC connectors, balanced 110
Ω
Phoenix connectors, or balanced 110
Ω
XLR connectors.
919050 Specifications
Input formats:
Digital-to-Analog Conversion:
Sampling rate:
Termination:
Analog out (of digital source),
S/N:
THD (full output):
Max output of analog out:
D to A gain calibration,
(dB = dBFS):
Standard input connectors:
Optional input connectors:
Standard output connectors:
Optional output connectors:
Error Indication:
AES/EBU or SPDIF
24-bit low jitter
32 kHz to 48 kHz
Removable (DIP switch selectable)
Greater than 96 dB
Less than 0.008%
+24 dBv (0 dBv = 0.775 vRMS)
+8 = -20, +4 = -20, +6 = -9, 0 = -18 (DIP switch selectable)
BNC: 75
Ω
, unbalanced
Phoenix or XLR: 110
Ω
, balanced
BNC: 75
Ω
, unbalanced
Phoenix or XLR: 110
Ω
, balanced
Two Bi-Color LEDs (on front panel):
Green = OK
Red = Error, no lock to signal, or no signal.
AES to Analog Converter Module (919050 PCB)