www.wobit.com.pl
Manual -MD150T – 27.10.2014 – v.1.3
page 10
3. P3-H
- hysteresis level of activation/deactivation of PK1 and PK2 outputs
4. MODE
- output operating mode:
Mode 0
– Absolute with two thresholds. Activation of PK1 and PK2 outputs is realized after
reaching of P1 and P2 values, respectively.
Mode 1
– Reverse with two thresholds. Operation is similar to the above mode. Deactivation
of PK1 and PK2 outputs is realized after reaching of P1 and P2 values, respectively.
6.
Password protection
Access to the process display settings can be password protected (parameter 11. PAS). There are 3
protection levels available. Protection level is set with the first digit, and the last 4 digits are used for
password entry.
0-0000
4-digit password (0-9999)
Protection level:
0-Settings protection above
12. DP
parameter
1-Settings protection above
3. P3-H
parameter
2-Protection of all settings
If the digital processing unit is password protected, then
after switching to protected settings the display shows
0000 value – enter previously set password. The password
can be deactivated by switching the parameter 18.PAS and
setting 0000 value.
Menu protection level
1. P1
2. P2
3. P3-H
4. MODE
5. TARA
6. OFFS
7. UNIT
8. RATE
9. FILT
10. TRA
11. TSE
12. DP
13. RS1
14. RS2
15. BEP
16. LED
17. FAC
18. PAS
2
1
0
Fig. 2 Example of PK1 relay output activation depending on P1 and P3H setting
and operatingl mode
(MODE).
Measurement value '
P1+P3H P1
P1-P3H
PK1
relay
status
(MODE=0)
PK1
relay
status
(MODE=1)