Figure 7-4. Packaging—carton

7.3. MSL level

The IMQ6 module has an MSL level of 3.

Summary of Contents for IMQ6

Page 1: ...1 37 User Manual Normal Internal Use Confidential Restricted Confidential User Manual Project Name IMQ6 Module Author Wistron NeWeb Corporation Revision 0 3 Revision Date 2020 11 28...

Page 2: ...t Information Technical Support website https SupportIoT wnc com tw Company Website www wnc com tw Revision History Rev Author Summary of Changes Date 0 1 WNC First release 2020 09 15 0 2 WNC Update S...

Page 3: ...HOUT PRIOR WRITTEN PERMISSION FROM WNC LIMITATION OF LIABILITY THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS PURELY FOR DESIGN REFERENCE AND SUBJECT TO REVISION BY WNC AT ANY TIME NOTHING IN T...

Page 4: ...ce 7 1 5 Environmental Specifications and Certifications 7 1 5 1 Environmental Specifications 7 1 5 2 Certifications 8 1 5 3 Green Product Compliance 8 2 Pin Definitions 8 2 1 LGA Module Pin Diagram 8...

Page 5: ...ons 18 4 Software Interface 18 4 1 Support tools 18 4 2 USB interface 18 5 Mechanical 19 5 1 PCBA Form Factor 19 6 Design Guide 22 6 1 Power supply 22 6 2 RF connection 23 6 3 Reflow 26 7 Labeling and...

Page 6: ...ART GPIO I2C and USIM 1 1 RF band support This section lists the main features and functions that the IMQ6 module supports Table 1 1 specifies wireless technologies supported Module LTE CAT M1 LTE CAT...

Page 7: ...h the 104 pads on the bottom side of a PCB 1 4 Environmental Specifications and Certifications 1 4 1 Environmental Specifications The environmental specifications for both operating and storage condit...

Page 8: ...above refer to ambient temperatures 1 4 2 Certifications The IMQ6 module is certified to be compliant with PTCRB GCF CE FCC regulations and standards 1 4 3 Green Product Compliance RoHS 2011 65 EU 2...

Page 9: ...dential Restricted Confidential Figure 2 1 LGA pad diagram top view 2 2 LGA Module Pin Definitions A complete list with related details for the module pinout are listed in the Table below Pin No Pin d...

Page 10: ...idential Restricted Confidential 7 GND 0 8 GND 0 9 NC 10 GND 0 11 GND 0 12 GND 0 13 GND 0 14 GND 0 15 RF_1 LTE TRX 16 GND 0 17 GND 0 18 GND 0 19 GND 0 20 GND 0 21 RF_2 GNSS 22 GND 0 23 GND 0 24 GND 0...

Page 11: ...8 4 5 40 VCC4 3 3 3 8 4 5 41 VCC5 3 3 3 8 4 5 42 VCC6 3 3 3 8 4 5 43 NC 44 GND 0 45 GND 0 46 GPIO46 1 7 1 8 1 9 47 GPIO47 1 7 1 8 1 9 48 GPIO48 1 7 1 8 1 9 49 GPIO49 1 7 1 8 1 9 50 GND 0 51 GND 0 52...

Page 12: ..._CTS 1 7 1 8 1 9 93 UART0_TX 1 7 1 8 1 9 94 UART2_TX 1 7 1 8 1 9 95 UART0_RX 1 7 1 8 1 9 96 UART2_RX 1 7 1 8 1 9 97 UART0_RTS 1 7 1 8 1 9 98 GPIO98 1 7 1 8 1 9 99 GPIO99 1 7 1 8 1 9 100 GPIO100 1 7 1...

Page 13: ...RFFE3_CLK GPIO138 1 7 1 8 1 9 139 GND 0 140 RFFE3_DATA GPIO140 1 7 1 8 1 9 141 WWAN_STATE 1 7 1 8 1 9 142 Power on 1 7 1 8 1 9 143 WAKEUP_OUT 1 7 1 8 1 9 144 WAKEUP_IN 1 7 1 8 1 9 145 RESET 1 7 1 8 1...

Page 14: ...0 219 GND 0 220 PS_HOLD 1 7 1 8 1 9 221 Force usb boot 1 7 1 8 1 9 222 UART1_RX UART 1 1 7 1 8 1 9 223 UART1_TX UART 1 1 7 1 8 1 9 Table 2 1 Module pin definitions 3 Electrical Specifications 3 1 Powe...

Page 15: ...71 V 1 8 V 1 89 V Table 3 1 Power supply 3 2 RF Specifications 3 2 1 Band support LTE CAT M1 Uplink MHz Downlink MHz LTE Band 2 1850 1910 1930 1990 LTE Band 3 1710 1785 1805 1880 LTE Band 4 1710 1755...

Page 16: ...1990 Table 3 2 Band support 3 2 2 Bandwidth support Band Bandwidth 1 4 MHz 3 MHz 5 MHz 10 MHz 15 MHz 20 MHz LTE Band 2 LTE Band 3 LTE Band 4 LTE Band 5 LTE Band 12 LTE Band 13 LTE Band 20 Table 3 3 L...

Page 17: ...RBs QPSK dBm 17 3 22 7 Band Items Parameter Unit Min Typ Max GSM 850 Max TX power dBm 31 35 GSM900 Max TX power dBm 31 35 DCS1800 Max TX power dBm 28 32 PCS1900 Max TX power dBm 28 32 Table 3 4 Condu...

Page 18: ...RX Sensitivity dBm 102 GSM900 RX Sensitivity dBm 102 DCS1800 RX Sensitivity dBm 102 PCS1900 RX Sensitivity dBm 102 Table 3 5 Conductive Rx sensitivity 3GPP Note 1 RF receiver specifications are define...

Page 19: ...Confidential 4 2 USB interface The IMQ6 module supports 3GPP s standard AT commands and proprietary AT commands 5 Mechanical 5 1 PCBA Form Factor The IMQ6 module has the same dimensions as the PCBA 1...

Page 20: ...20 37 User Manual Normal Internal Use Confidential Restricted Confidential Figure 5 2 Pad dimensions bottom view...

Page 21: ...21 37 User Manual Normal Internal Use Confidential Restricted Confidential Figure 5 3 Recommend PCB footprint...

Page 22: ...integrated power manager that enables single and direct voltage supply from the battery and reduces the overall bill of materials The typical voltage of 3 8V is recommended Schematic suggestion We hig...

Page 23: ...A VREF 300 mA 6 2 RF connection The IMQ6 module has three RF pads developers must connect them via 50 traces to the main board RF_1 LTE TRX Pin15 LTE GSM RX TX path RF_2 ANSS Pin21 GNSS path We recomm...

Page 24: ...Confidential Restricted Confidential Figure 6 1 RF pad layout suggestion The characteristic impedance depends on the dielectric of PCB the track width and the ground plane spacing Microstrip type is r...

Page 25: ...25 37 User Manual Normal Internal Use Confidential Restricted Confidential The RF trace of the test board which was used in the FCC test is defined as below Microstrip RF trace...

Page 26: ...is section details the recommended reflow profile when the module is mounted onto other boards Temp Region 1 2 3 4 5 6 7 8 9 10 11 Upper temp region 160 170 180 180 180 205 225 230 240 250 245 Lower t...

Page 27: ...I 48 U10 1 T1 2 J3 3 U42 4 Temp Difference Preheat from 140 190 C 81 48 81 13 81 94 79 07 2 87 34 36 32 48 Melt out Time 230 C 46 91 49 26 53 50 48 18 6 59 31 7 35 18 Max Temp 240 40 241 34 241 84 241...

Page 28: ...1 87 1 86 0 05 25 28 25 24 Process limit Solder Paste Lead free Profile feature Min Max Unit Gradient1 Target 1 5 100 C 150 C Time period 20 s 0 3 C S Preheat time from 140 C to 190 C 70 105 S Time ma...

Page 29: ...ial 7 Labeling and Packaging 7 1 Labeling Figure7 1 is a drawing showing a label for the IMQ6 module Figure 7 1 Label drawing TBD 7 2 Packaging Tape and Reel Package Modules are delivered in tape and...

Page 30: ...er Manual Normal Internal Use Confidential Restricted Confidential Figure 7 3 Packaging reel Single Package for Samples 50 pcs box no vacuum packaging must be baked for at least eight hours at 85 C be...

Page 31: ...31 37 User Manual Normal Internal Use Confidential Restricted Confidential Figure 7 4 Packaging carton 7 3 MSL level The IMQ6 module has an MSL level of 3...

Page 32: ...etween the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for...

Page 33: ...Canada avis d Industry Canada IC Cet appareil est conforme avec Industrie Canada exemptes de licence RSS standard s Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit p...

Page 34: ...ste ayant un gain sup rieur au gain maximal indiqu pour ce type sont strictement interdits pour une utilisation avec cet appareil Antenna List No Manufacturer Part No Antenna Type Peak Gain dBi 1 WIES...

Page 35: ...me indiqu dans ce manuel USERS MANUAL OF THE END PRODUCT In the users manual of the end product the end user has to be informed to keep at least 20cm separation with the antenna while this end product...

Page 36: ...n AC Alternating Current DC Direct Current ETSI European Telecommunications Standards Institute GND Ground GPS Global Positioning System GNSS Any single or combined satellite navigation system GPS GLO...

Page 37: ...PCM Pulse Code Modulation SIM Subscriber Identity Module SMA Surface Mount Antenna SPI Serial Peripheral Interface UART Universal Asynchronous Receiver Transmitter UIM User Identity Module USB Univers...

Reviews: