230 Volt Operation
If 230V, single phase operation is desired, the following instructions must be followed:
1. Disconnect the machine from the power source.
2. This bandsaw is supplied with four motor leads that are connected for 115V operation, as shown in
Figure A. Reconnect these four motor leads for 230V operation, as shown in Figure B.
3. The 115V attachment plug supplied with the bandsaw must be replaced with a UL/CSA listed plug
suitable for 230V operation. Contact your local Authorized JET Service Center or qualified electrician
for proper procedures to install the plug. The bandsaw must comply with all local and national codes
after the 230V plug is installed.
4. The bandsaw with a 230V plug should only be connected to an outlet having the same configuration.
No adapter is available or should be used with the 230V plug.
Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly
grounded. If you are not sure, have a registered electrician check the receptacle.