35
User Manual WMF Cup / WMF Cup&Cool
Appendix: Technical data
Appendix: Technical data
Technical Data for Cup&Cool
Version
Cup
Cup&Cool
narrow
wide
narrow
wide
9020
9020
9021
9021
Nominal power rating
(1
(Watt)
120–150
130–155
-
Heat output
(1
(Watt)
-
105
76
Mains power connection
1/N/PE 50/60 Hz/220–240 V
On-site power connection
Earthed socket outlet
Rated current (A)
without LED
with LED
-
-
0.29
0.30
0.29
0.31
Coolant
R-600a (GWP3), Category N/4
(CFC free)
Amount of coolant
12 g
11 g
Illumination
LED class 1
On-site fuses
1 x 16 A
Cup capacity per shelf
Espresso cups 60 mm in diameter;
two layers
Coffee cups 80 mm in diameter;
one layer
66
15
80
22
66
15
80
22
Number of shelves
4
4
3
2
Total cup capacity
60–264
88–320
45–198
44–160
Shelf temperature
max. 80 °C
(2
Milk capacity
-
4 litres
9.5 litres
External dimensions in mm
Width
Height
Depth
285.4
530
538.3
368
530
538.3
285.4
530
565.1
368
530
566.6
Weight empty (approx. kg)
27
28
31
32
Continuous sound pressure level
(Lpa)
< 70 dB(A)
(3
We reserve the right to make technical modifications.
(1
For special models see model label, values given above are for the basic model.
(2
Because of type of construction used, the lowest shelf is about 8 °K cooler.
(3
A-evaluated sound pressure level Lpa (slow) and Lpa (impulses) at operating personnel workplace is under 70 dB(A) in any