User Manual WMF 1200 F
Technical data
Installation clearances For operating, service and safety reasons the machine
should be installed with a clearance of not less than
50 mm at the back and sides from the building or
non-WMF components. A minimum working space of
800 mm in front of the coffee machine is recommended.
A clear height of 1,100 mm from the top of the
supporting surface should be ensured. The height
of the installation surface above the floor is at least
850 mm. If the coffee machine connections are to be run
downwards through the counter, please make space for
the lines, which can reduce the usable space below the
machine.
Installation dimensions
of the water filter
See the User Manual for the water filter.
these specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. it may be necessary
to also observe additional country-specific regulations. outside the EU
countries, acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The local power supply must be constructed according to IEC 364 (DIN VDE 0100).
To improve safety, the device should be fitted with an FI 30 mA earth leakage
current circuit breaker complying with EN 61008. (Type B residual current circuit
breakers provide reliable tripping even if the fault current is smooth. This ensures
a high level of safety.) Near the device or about 30 cm below the counter top there
should be a shockproof socket as a single-phase connection installed locally on
the rear or side wall of the counter substructure or a country-specific single-phase
socket. If the mains cable for this device is damaged then it must be replaced by
our service personnel or a similarly qualified person, in order to prevent hazards.
The mains cable must not come into contact with hot surfaces. The mains switch
and plug top are part of the on-site installation. The coffee machine may not
be fitted with a fixed permanent mains connection if installed on a transporting
trolley (a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system.
(See EN 60309)