Descaling
▪ Insert the paper filter and place the jug (3) in the machine. Any more substantial amounts of
limescale residue collect on the filter paper and thus prevent the spout becoming clogged.
▪ Add a portion (100 ml) of
Cromargol®
to the water tank (4) and top off with tap water to the
8-cup mark
and turn on the device.
▪ Dose and use other descaling agents according to the manufacturer’s instructions.
▪ After the descaling solution has passed through, empty the jug (3), switch off the device and allow
to cool for 5 minutes.
▪
Measure out and use other descaling agents according to the manufacturer’s instructions
.
Important
: Then to rinse, fill the tank (4) to the
8-cup mark
with fresh tap water and allow this to
run through the machine. Then rinse the filter and jug (3) under running water.
Note:
In the event of heavy calcification, repeat the descaling process.
For UK use only
▪ This product is supplied with a 13 A plug conforming to BS 1363 fitted to the mains lead. If the
plug is unsuitable for your socket outlets or needs to be replaced, please note the following. If the
plug is a non-rewireable one, cut it from the mains lead and immediately dispose of it. Never insert
it into a socket outlet as there is a very great risk of an electric shock.
▪ The replacement of the plug at the mains lead has to be done according to the following
instructions:
Warning
-
This appliance must be earthed
Important
: The wires in this mains lead are coloured in accordance with the following code:
green/yellow Earth
blue
Neutral
brown
Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
⋅
the wire which is coloured green and yellow must be connected to the terminal which is
marked with the letter E or by the earth symbol , or coloured green or green and yellow,
⋅
the wire which is coloured blue must be connected to the terminal which is marked the letter
N or coloured black,
⋅
the wire which is coloured brown must be connected to the terminal which is marked with
the letter L or coloured red.
▪ If a 13 A (BS 1363) plug is used it must be fitted with a 13 A fuse conforming to BS 1362 and be
ASTA approved. If any other type of plug is used, the appliance must be protected by a 10 A fuse
either in the plug or adapter or at the distribution board.
If in doubt - consult a qualified electrician.
▪ Never use the plug without closing the fuse cover.