EU
LED 11
SIM status / SIM or PIN
failure
Lighting continuously, while the modem is not registered on
the network and while no RSS response (SIM is ok)
When the SIM PIN is okay: led is active
If no SIM can be detected or the SIM PIN is wrong:
blinking once
per second (slow flashing)
This LED also signs the RSSI signal strength: X number of flashing
during 10-15 seconds, repeated (RSSI value, where X value can be:
1,2,3 or 4)
The number of RSSI flashing can be:
o
RSSI <= -98
1
flashing
o
RSSI > -98 and <= -83
2
flashing
o
RSSI > -83 and <= -68
3
flashing
o
RSSI > -68
4
flashing
LED 2
Firmware status
Default: the LED is inactive
During communication: the LED is flashing
Over the factory default settings, the operation of the LED signals and its sequence can be changed by
the
WM-E Term
®
configuration tool.
In the program, at the Standard Meter Interface parameter group, where you can define one of the
following functions of the leds (LED1..LED3) according the next list:
Further configurable LED status signals:
LED status
Event
E-meter relay status –
Relay* output status (not
available on this modem)
Default: “Ready” / stand-by – the LED is flashing once per
second
“Active” mode – at *relay switching turns on the LED
“Normal” mode – at *relay release turns off the LED
M-Bus status
Not used
Firmware status
If the modem firmware starts the LED will be active
If the meter
modem connection was built up, the LED is
flashing twice per second
Network status and
access technology
Network registration: the LED is active
During the network searching: flashing once per second
When connected to the network and the IP connection is fine:
flashing twice per second
When the mobile network access technology was changed: there
will be a quick flashing:
o
2G
2 flashing / second
o
3G
3 flashing / second
o
4G
4 flashing / second
If there is no available network: the LED is inactive
Meter status with IEC
polling
When the modem
meter starts the communication, the LED is
flashing once per second
.
When the meter answers to the modem during the communication,
the LED will be turned on.
When the modem cannot communicate with the meter
permanently, the LED will be turned off.
AMM (IEC) client state
By default, or in case of finishing the communication of the
modem
EI client the LED is turned off
During the modem
EI client ** connection build-up the LED is
flashing shortly once in every second
The EI client** at login requrest – flashing once per second
The EI client**
modem communication was built
–
the LED is
active
*The listed relay can be used to control the power supply of the e-meter. This is not used for tariff change!
**The EI client is the transparent TCP channel from the modem to the EI server