WLD-TEC gasprofi 1 SCS micro Instruction Manual Download Page 15

Sales department

Spandauer Weg 1
D - 37085   Göttingen
Phone : +49 (0)551/793789
Fax : +49 (0)551/793707

Internet: http://www.wld-tec.com

05/06

Production und Service:

Halle-Kasseler Straße 49
D - 37318 Arenshausen
Phone : +49 (0)36081/68940
Fax : +49 (0)36081/68942

Email:  [email protected]

WLD - TEC

 

GmbH

Summary of Contents for gasprofi 1 SCS micro

Page 1: ...The smallest laboratory gas burner with more safety EN Instruction manual DIN30665 part1 gasprofi 1 SCS micro...

Page 2: ...Connector for foot pedal 11 Power connector for 9 V DC 12 Gas inlet R 1 4 L 13 Holding device for inoculation loop holder 14 Burner head screw 15 Monitor electrode 16 Ignition electrode 17 Active noz...

Page 3: ...with two wrenches Ensure gas proofness with a suitable test fluid equipment DO NOT seal the swivel nut with Teflon tape etc Keep hands or other parts of the body away from the burner orifice 9a Do no...

Page 4: ...lockwise Remove the active Nozzle N for natural gas 17 in the same way and exchange the nozzles ATTENTION Before mounting a nozzle check the O Ring 26 Replace the sealing if damaged or worn Art No 8 0...

Page 5: ...By turning the function knob all programs can be selected and the IR sensor detection range can be adjusted 2 2Operation Applicationprograms BUTTON StartStop LED Button is on The flame is ignited by...

Page 6: ...ubleClick IR Sensor 6 by passing you hand over it twice Whentheneededburningtimeisreachedpressthefunctionknob 1 tostoptheflame Thereby the reached burning time is memorized and the application program...

Page 7: ...or programs in the button function and in the foot pedal operating mode StartStop is limited to 30 seconds see paragraph 2 2 If burning times longer than 30 seconds are required in case of a clogged b...

Page 8: ...itor the burner head needs to be reinstalled prior a reset is possible 5 Cleaning and sterilizing Allow sufficient time for burner orifice 9 9a to cool down before disassembling or cleaning the burner...

Page 9: ...he air knob 2a any longer During the use of the turbo flame most of the needed air is taken inside through the open burner shaft Remounting the cover of burner shaft see paragraph 5 2 7 Tilt adjustmen...

Page 10: ...Notes...

Page 11: ...rrectly Clean this areas with a brush The burner head can be cleaned with customary commercial disinfectants or it can be sterilized in an autoclave or washed in a dishwasher In operating mode Pedal S...

Page 12: ...e see paragraph 4 Green LED Button Standard or StartStop blinks 3x Flame faliure see paragraph 4 Green LED Button Standard or StartStop blinks 4x Overtemperature see paragraph 4 Green LED Button Stand...

Page 13: ...connection 1 ElektromagnetischeVertr glichkeit Electromagnetic Compatibility Directive 1 1 EN61326 1 2006 ElektrischeBetriebsmittelf rLeittechnikundLaboreinsatz EMV Anforderungen EN 61326 1 2006 Elect...

Page 14: ...g h liquid gas Continuous cartridge operation CV 360 40 min Express 444 50 min CG 1750 150 min C 206 170 min CP 250 210 min CV 470 370min Temperatures Flame temperature 1350 C on liquid gas 1300 C on...

Page 15: ...85 G ttingen Phone 49 0 551 793789 Fax 49 0 551 793707 Internet http www wld tec com 05 06 ProductionundService Halle KasselerStra e49 D 37318Arenshausen Phone 49 0 36081 68940 Fax 49 0 36081 68942 Em...

Reviews: