WizFi210
Programmers’ Guide
(WIZnet Co., Ltd.)
2-22
2.1.9.
Battery check
This category is for commands related to handling Battery when user use Battery with
WizFi210/220.
Command
Category
Description
AT+BCHKST
RT
Format
AT+BCHKSTRT=
<Batt.chk.freq>
Meaning
Start checking battery
each 0 < Batt.chk.freq≤ 100 packets transmitted.
<Batt.chk.freq>
: Battery Check Frequency
Response
[OK]
AT+BATTLVL
SET
Format
AT+ BATTLVLSET=
<Warning Level>,<Warning Freq>,<Standby
Level>
Meaning
Set the battery warning/standby level to enable WizFi210/220’s
internal battery measuring logic
.
Response
[OK]
AT+BCHK
Format
AT+BCHK=
<Batt.chk.freq>
Meaning
Reset value of battery check frequency.
<Batt.chk.freq>
: Battery Check Frequency
Response
[OK]
AT+BCHKST
OP
Format
AT+BCHKSTOP
Meaning
Stop checking battery
.
Response
[OK]
AT+BATTVAL
GET
Format
AT+BATTVALGET
Meaning
Retrieve the most recent battery check value.
Response
[OK]
Table 10 List of commands for Battery check