background image

A serial to Ethernet test can also be performed by using the hyper terminal. 

 

In the same way, input any character in the screen of terminal program for network, and check if 

same character is displayed in the screen for serial (Ethernet to Serial)   

 

  The  above test can also be performed in a program called, “Device Terminal program”, which is easy 

and simple to use.   

               

 

                                                Device Terminal Program 

Device  Terminal  is  a  program  which  integrates  both  serial  and  network  communications  into  one  user 

interface so that you can test your WIZnet gateway module easily.   

As shown in above  Figure,  the upper  part  of  the program  allows  you to configure  your serial setting  of 

WIZ610Wi. By clicking the “Open” button, serial communication is enabled. 

The lower part of the program allows you to configure the network settings. You can test both TCP Client 

and TCP Server modes at the same time. If the Server Mode is enabled, Device Terminal will operate as 

server mode, and the WIZ610Wi module will work as client mode. The PC where the Device Terminal is 

operating  will  work  as  a  server,  the  IP  address  of  the  PC  should  be  set  as  Server  IP  of  the  module.  If 

Server mode is not checked, Device Terminal will operate as client mode, and the module as server. For 

the  IP  address  and  port,  please  input  your  IP  address  and  port  number  of  WIZ610Wi  and  click  the 

“Connect” button to start a network communication. 

메모

 [q7]: 

Very vague 

instruction….   

 

메모

 [q8]: 

I think this is 

stating the obvious 

Summary of Contents for WIZ610wi

Page 1: ...Reserved For more information please visit our website at http www wiznet co kr WIZnet s Online Technical Support If you have any questions about our products please visit our website and post your q...

Page 2: ...C CL LI IC CK K...

Page 3: ...PYRIGHT NOTICE Copyright 2008 WIZnet Inc All Rights Reserved Technical Support support wiznet co kr Sales Distribution sales wiznet co kr For more information visit our website at http www wiznet co k...

Page 4: ...PC The default IP address and Subnet Mask of WIZ610Wi are 192 168 1 254 and 255 255 255 0 respectively Please configure the IP address of your PC as 192 168 1 XXX and Subnet Mask as 255 255 255 0 Ste...

Page 5: ...DHCP server WIZ610Wi assigns IP address Gateway Mode In this mode WIZ610Wi is a bridge for Ethernet to the MII interface Regardless of DHCP server operating at the upper level WIZ610Wi assigns IP add...

Page 6: ...a name of your choice Channel A different channel should be selected when your device experienced interferences from other wireless network The default channel is set as 1 Security The default securi...

Page 7: ...DP or TCP Mode Select a mode Server Client Mixed Server IP Port At the Client or Mixed mode you should set the server IP address WIZ610Wi will try to connect to this server IP address Configure Baud r...

Page 8: ...Connect to WIZ610Wi in the Wireless Network Setting of your PC Open another Terminal program and input IP address and Port Number of WIZ610Wi...

Page 9: ...the Hyper Terminal for Serial In the example below 01234567890 is input The same characters are outputted in the Hyper Terminal for Network A Serial to Wireless LAN test was performed Received Data by...

Page 10: ...configure your serial setting of WIZ610Wi By clicking the Open button serial communication is enabled The lower part of the program allows you to configure the network settings You can test both TCP...

Page 11: ...When serial and network terminals are connected input any character in the Data Input window and click Send button You can check the data is transferred into thes another window...

Reviews: