W5500S2E-Z1 serial to Ethernet module
W5500S2E-Z1 user manual
into EEPROM after executing this command.
6.4.2.3
Echo (AT+ECHO)
Command format
Parameters / Description
Usage
AT+ECHO=<echo>\r\n
<echo>
0: Close Echo feature
1: Open Echo feature (default)
Define new value
AT+ECHO?\r\n
Query current value
Return value
[ECHO] Value is: <echo>\r\nOK\r\n
Echo means WIZS2E module could directly return any input values to the serial interface. Thus, this option may
help some users working more easily through serial terminal software. However, this may cause trouble if the serial
is connected to an embedded system. Turn off this function in this case.
6.4.2.4
List of commands (AT+LIST)
Command format
Parameters / Description
Usage
AT+LIST?\r\n
Nil
Query current value
return value
<AT command list>\r\nOK\r\n
6.4.2.5
List of default / current values (AT+PRE)
Command format
Parameters / Description
Usage
AT+PER?\r\n
Nil
Query current value
return value
DEFAULT:\r\n<default list>\r\nCURRENT:\r\n<current list>\r\n
6.4.2.6
Factory reset (AT+DEFAULT)
Command format
Parameters / Description
Usage
AT+DEFAULT=<pass>\r\n <pass>: [device password]
Reset to factory
default settings
Return value
OK\r\n<factory info>\r\n
Exact password must be imputed to execute this command. When this command is successfully executed, the module
restores the factory default settings and enters to AT command mode. Device password can be queried and set through
“AT+PASS”.
6.4.2.7
Reset (AT+RESET)
Command format
Parameters / Description
Usage
AT+RESET=<pass>\r\n
<pass>: [device password]
Reset the module
Return value
OK\r\n<factory info>\r\n
Exact password must be imputed to execute this command. The module will be in data mode after reset. Device
password can be queried and set through “AT+PASS”.
6.4.2.8
Ethernet send counter (AT+NETSEND)
Command format
Description
Usage
AT+NETSEND?\r\n
Nil
Query the byte of data sent by Ethernet interface