Wizard-tk on-ac-30_40 User Manual Download Page 2

3.  Technical parameters 

NO 

Specification 

Parameter 

Reading distance 

5-10cm 

Working temperature 

-20 

 -70 

 

Working humidity 

0-95% 

Static electricity 

≤50mA 

Working voltage 

DC 12 V 

Static current 

50mA 

 

4.  Function setting method 

4.1  the facorty default settings 

The initial opening password

 7890, 

programming code

 123456. 

4.2  quick operation settings 

(1), Swipe the main card, enter the programming system state 

(2), Swipe added card, enter the add user state 

(3), Swipe deleted card, enter the delete user state 

4.3  modify the programming code and set up the master card 

A, press  *      Programming code   #   0   The new password    #  

The new password   # 

Note: A beeping said succedd (password length for 1-8 code). 

B,Press  *      Programming code    #    0    Swipe card    

Note: A beepiing said setting the main card successfully. 

 

4.4  Add card type users 

press  *      Programming code   #   1   Four user id    #   Read the card   

           

Note: The four user id is 

random

, user id automatically add 1 when continue read card. 

4.5  add password type users 

press  *      Programming code   #   2   Four user id  The user password  # 

Note: Four user id ( For example: 1 enter 0001), the user password length for 0-4. 

A beeping said add user password type user operation is successful. You can add  

password type continuously with continue to input the user code. 

(when opening the door, please input programming code and user password end with # ) 

4.6  add card+password type users 

press  *      Programming code   #   3   Four user id  Four user password  # 

Summary of Contents for on-ac-30_40

Page 1: ...ta copy and backup to the same series if access control Circumscribed humanized tamper alarm function Can be used as card reader or standalone access controller Extend wiggins dummy WG2 34 input and o...

Page 2: ...The new password Note A beeping said succedd password length for 1 8 code B Press Programming code 0 Swipe card Note A beepiing said setting the main card successfully 4 4 Add card type users press P...

Page 3: ...rd press Programming code 6 Four user code Four new password Note It can be operated continuously in the condition of programming 4 10 modify the door delay time press Programming code 7 Enter delay t...

Page 4: ...6 Data copy 1 TXD connect RXD RXD connect TXD to the same type access control 2 Press copy code 13825256 to the main access controller which with date 3 The green light flashing on both of the access...

Page 5: ...eader 8 Wiring diagram 8 1 Common power supply diagram Figure 1 Note Please change the operating mode when use access control machine as access control rader TXD and RXD is Data copying interface two...

Page 6: ...am Red 12V 12V DC regulated power input Black GND 12V DC regulated power input Yellow NO Relay normally open end connect positive electric lock Grey COM Relay publick end connect GND Purple NC Relay c...

Page 7: ...to factory Before installation on the wall if you want to punch please check wiring and line pipe Carefully for unnecessary trouble etc when drilling or fixing clamp please use safety Glasses It is wi...

Reviews: