Wixey WR525 Type 2 Instructions Download Page 4

 

4

9-Trouble Shooting 

 

Readout issues 
 

The Digital Readout will not function properly or display numbers correctly unless the cable is connected to 
both the display and sensor. Do not install the batteries or turn it on until everything is properly connected. 
 

NOTE:  If you purchase a different length Cat 5E cable to use make sure that it is a shielded style 

noted by the metal encased plug. 
 
 
 
 
 
Unstable constantly scrolling numbers 

  Insure the sensor is properly installed on the scale. 

  Remove the battery, wait 30 seconds and replace it. 

 
Flashing digits, dim, or no display 

  Install new batteries. 

  Clean batteries and battery contacts. 

 
Frozen display 

  Remove the battery, wait 30 seconds and replace it. 

 
Loses calibration 

  Make sure that your machine is properly grounded. 

  Route the cable away from electric motors or other electrical controls. 

  Check for dirt on the scale or inside the sensor. Remove and clean if needed. 

  Check for static discharges from a nearby dust collector or other source 

Note: If a static discharge from your finger zaps the readout or a nearby dust collector 
happens to zap your machine it can cause this error. Make sure the dust collector is properly 
grounded and the dust port on your saw is grounded to the ground wire inside the dust 
collector hose.  

 
 

Accuracy Issues 
 

Small accuracy errors of 1/16” or less 

  Check for loose or flexing brackets. 

  Make sure that the scale is perpendicular to the top plate in all planes. 

 
Large accuracy errors of .200” or more 
 

  An error of exactly .200" is a very common error number with these devices or even a multiple of 

it  like  .400,  .600,  1.200  etc.  Usually  this  only  happens  when  the  readout  is  either  moved  very 
quickly (more than 3 feet per second). Follow the same steps outlined in the “Loses calibration” 
section above

 
 
 

 

 
 

Scale 

Sensor 

Sensor decal 

 

Reviews: