background image

WITURA

 

TECHNOLOGY

 

SDN

 

BHD

 

|

                         

WT

1672A GSM

 

Power

 

Outage

 

Alarm User

 

Manual

 

V1.8

 

14

 

 

Warranty

 

 

Witura

 

Technology

 

Sdn

 

Bhd

 

warrantees

 

the

 

WT

1672A

 

GSM

 

Temperature

 

Alert

 

and

 

Monitoring

 

System

 

against

 

defective

 

parts

 

and

 

workmanship.

 

Witura

 

Technology

 

Sdn

 

Bhd

 

shall,

 

at

 

its

 

option,

 

repair

 

or

 

replace

 

the

 

defective

 

equipment

 

upon

 

the

 

return

 

of

 

such

 

equipment

 

to

 

any

 

Witura

 

branch.

 

This

 

warranty

 

applies

 

ONLY

 

to

 

defects

 

in

 

components

 

and

 

workman

ship

 

and

 

NOT

 

to

 

damage

 

due

 

to

 

causes

 

beyond

 

the

 

control

 

of

 

Witura,

 

such

 

as

 

incorrect

 

voltage,

 

lightning

 

damage,

 

mechanical

 

shock,

 

water

 

damage,

 

fire

 

damage,

 

or

 

damage

 

arising

 

out

 

of

 

abuse

 

and

 

improper

 

application

 

of

 

the

 

equipment.

 

 

Note:

 

Wherever

 

possible,

 

return

 

only

 

the

 

PCB

 

to

 

Witura

 

Service

 

Centres.

 

DO

 

NOT

 

return

 

the

 

enclosure.

 

 

 

The

 

WT

1672A

 

is

 

a

 

product

 

of

 

Witura

 

Technology

 

Sdn

 

Bhd

 

And

 

is

 

manufactured

 

by

 

Shenzhen

 

Witura

 

Telecommunications

 

Co.,

 

Ltd.

 

 

 

 

WARNING

 

For

 

safety

 

reasons,

 

only

 

connect

 

equipment

 

with

 

a

 

telecommunications

 

compliance

 

label.

 

This

 

includes

 

customer

 

equipment

 

previously

 

labelled

 

permitted

 

or

 

certified.

 

Summary of Contents for WT-1672A

Page 1: ...WITURA TECHNOLOGY SDN BHD WT 1672A GSM Power Outage Alarm User Manual V1 8 1 WT 1672A GSM Power Outage Alarm USER MANUAL VERSION 1 2 UPDATED AUG 2013...

Page 2: ...to switch on the generator backup battery and etc The GSM Remote Control system supports timer function the user can set schedule to turn on off the switch For example put your pump motor on a schedu...

Page 3: ...stently until it locates the network A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On The Status of the Relay will remain as on unt...

Page 4: ...the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185299 your phone number 2 3 4 5...

Page 5: ...t back to the factory default This means you already reset the unit to factory default Now you can start to call again to set the administrator This method of setting is only allowed to set 1 administ...

Page 6: ...he factory password to your new password Enter the factory password follow by your new password 3 Add telephone number into the admin list 1 1 telephone number For example set Admin number 18617185300...

Page 7: ...larm Function 10 N When Sending 10 0 Alarm switch OFF 2013 10 10 16 28 Thu N 0 Deactivate Alarm Function N 1 Activate Alarm Function Factory Default Setting as N 1 For example if you want to activate...

Page 8: ...time is up Master relay OFF 2013 10 10 16 33 Thu Note if the system is only ON after the scheduled time the unit will still running accordingly System startup Master Replay OFF 2013 10 10 16 33 Thu N...

Page 9: ...0 Thu When sending command 22 1 Status switch ON 2013 10 10 17 08 Thu N 1 means after make the phone call to the system it will return the SMS for the status to the caller N 0 means after make the pho...

Page 10: ...N 1 means switch on the relay by SMS Message N 0 means switch off the relay by SMS Message 18 Turn on off the administrative call 25 N 0 Call Switch OFF 1 Call Switch Start Up Alarm 2 Call Switch AC d...

Page 11: ...ect the cable to terminals 110V 220V N ensuring positive is connected to terminal 110v 200V switch on the power supply the red power LED will light indicating power is present the blue network LED ind...

Page 12: ...d person Connector 1 2 3 4 5 6 Board Label J3 Power Supply Description Relay Power Supply 1 Connection Details NC No COM E N L Note 1 The Relay J3 Was using for turning on and off the electrical appli...

Page 13: ...has been activated and that the PIN request has been disabled If the unit is in a low signal strength area consider using an external GSM antenna or changing to another network provider 3 I am not rec...

Page 14: ...workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and impro...

Reviews: