4
|
P a g e
User Manual V1.3 Updated Nov 2013
Adding
and
Deleting
Numbers
in
the
Security
List
The
system
will
accept
up
to
99
Mobile
or
Landline
numbers
that
are
authorized
to
access
the
system
and
to
store
these
numbers
in
the
authorized
list
you
can
use
the
following
format
as
from
01
up
to
99
and
to
store
number
one
number
in
the
list
you
would
send
the
unit
the
following
SMS
Message
assuming
the
number
as
023456789
and
it
is
not
required
to
enter
the
(
0
)
in
the
number
as
the
system
will
read
the
last
8
digits
as
confirmation
of
the
number.
PWD654321#WHL01=23456789
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
WHL01:
23456789
This
format
applies
up
to
the
last
number
as
#PWD654321#WHL99=
To
delete
any
numbers
in
the
list
you
would
send
the
following
SMS
Message
to
the
unit
and
assuming
you
were
deleting
telephone
number
one
of
the
authorized
list
as
WHLO1=23456789
#PWD654321#WHL01D
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
WHL01D
<OK>
and
number
1in
the
authorized
list
has
been
deleted
.
Checking
a
telephone
Number
in
the
Security
List
If
you
want
to
check
any
number
in
the
authorized
list
you
can
do
so
by
sending
the
following
SMS
Message
to
the
unit
as
assuming
you
are
checking
number
one
in
the
authorized
list.
#PWD654321#WHL01?
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
WHL01:
23456789
Setting
up
the
Output
relay
one
Latching
time
when
called
This
function
sets
the
actual
latching
time
when
you
call
the
unit
and
is
factory
pre
‐
set
at
1
second
but
it
is
possible
to
extend
this
latching
time
up
to
60
seconds
To
reset
the
latching
time
to
5
seconds
for
say
a
Magnetic
Lock
you
would
send
the
following
SMS
Message
to
the
unit.
#PWD654321#GOT05
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
GOT:
05
and
the
Output
Relay
one
will
now
latch
for
5
seconds
whenever
the
unit
is
called
Temporary
latching
any
or
both
relays
It
is
possible
to
temporary
latch
both
relays
independently
and
in
the
case
of
relay
one
this
does
not
affect
the
default
setting
of
the
GOT
command.
Both
relays
can
be
temporary
latched
from
1
second
up
to
65,000
i.e.
18
hours
and
to
latch
Relay
one
for
a
period
of
3600
seconds
you
would
send
the
following
SMS
message
to
the
unit.
#PWD654321#RLY1=03600
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
RLY1:
03600
and
Relay
one
has
latched
for
a
period
of
3600
seconds.
To
Latch
Relay
two
for
a
period
of
3600
seconds
you
would
send
the
following
SMS
Message
to
the
unit.