background image

1

 

|

 

P a g e

 

 

User Manual V1.3 Updated Nov 2013

 

 

 

 

 

Introduction

 

 

The

 

Witura

 

WT

010

 

has

 

been

 

designed

 

to

 

operate

 

Gates

 

and

 

other

 

electrical

 

devices

 

using

 

your

 

existing

 

Mobile

 

Phone

 

or

 

Land

 

Line

 

and

 

also

 

eliminating

 

the

 

problems

 

that

 

occur

 

with

 

low

 

range

 

wireless

 

remote

 

controls

 

as

 

this

 

system

 

has

 

no

 

range

 

barriers.

  

This

 

system

 

allows

 

the

 

administrator

 

or

 

user

 

to

 

operate

 

two

 

separate

 

relays.

 

One

 

using

 

caller

 

ID

 

to

 

active

 

relay

 

one

 

automatically

 

with

 

a

 

voice

 

call

 

or

 

alternately

 

it

 

is

 

possible

 

to

 

SMS

 

the

 

system

 

to

 

activate

 

Relay

 

2

 

to

 

perform

 

another

 

function.

 

Another

 

feature

 

is

 

an

 

Alarm

 

Input

 

function

 

which

 

has

 

the

 

ability

 

to

 

send

 

up

 

to

 

8

 

separate

 

SMS

 

alerts

 

in

 

the

 

event

 

of

 

an

 

incident

 

such

 

as

 

a

 

power

 

failure

 

or

 

an

 

alarm

 

being

 

activated

 

and

 

a

 

personal

 

customized

 

message

 

can

 

be

 

programmed

 

into

 

the

 

system.

 

The

 

system

 

comes

 

with

 

an

 

in

build

 

power

 

supply

 

and

 

external

 

antenna

 

and

 

only

 

requires

 

a

 

valid

 

SIM

 

Card

  

 

WT-010 GSM Gate Opener

Product Model: WT-010 V2.0

Existing

 

Gate

 

Controller

 

WT

010

 

GSM

  

Gate

 

Opener

 

Electric

 

Gate

Summary of Contents for WT-010

Page 1: ...ctive relay one automatically with a voice call or alternately it is possible to SMS the system to activate Relay 2 to perform another function Another feature is an Alarm Input function which has the...

Page 2: ...l that the SIM Card is retained with enough credit at all times so as to be able to receive the SMS text alerts when making any changes to the system remotely even though the system will continue to p...

Page 3: ...between 1 and 31 and it is advised if you are registering a signal strength any lower then 5 or 6 it would be advised to add an additional external antennae to improve the signal strength or change t...

Page 4: ...sending the following SMS Message to the unit as assuming you are checking number one in the authorized list PWD654321 WHL01 and you should receive the following SMS message from the unit if sent cor...

Page 5: ...and RLOP2 0 Receiving SMS Text alerts and messages from the unit It is possible to receive SMS alert messages to confirm both relay latching has been implemented and also when the Relays Latch off In...

Page 6: ...if you want to send more than one message to one off the Administrators you would simply enter that administrator in the TEL list the number of times you want them to receive the SMS text alerts and...

Page 7: ...the CTC 5 or CTC 6 have to be programmed into the system otherwise the alert messages will not be sent and also the following alarm function must be turned on Turning the Alarm function On and Off The...

Page 8: ...R NUMBERS DELETE ALL USER NUMBERS GOT 01 60 RLY1 RLY2 RLOP1 RLOP2 TEL 01 08 CHANGE DEFAULT LATCHING TIME TEMPORARY LATCHING PERMINANT LATCHING ADD ADMINISTRATORS RERN STR CTR1 CTR0 SET ADMINISTRATOR M...

Reviews: