background image

MCZ Pellet Stoves 

 

Technical Training 

Summary of Contents for MCZ

Page 1: ...MCZ Pellet Stoves Technical Training...

Page 2: ...First Lighting Comfort Air Remote Control Black LCD Panel Active System Operating Parameters Emergency Panel Black LCD Panel Navigation Alarms Trouble Shooting Re Coding the Motherboard Scheduled Main...

Page 3: ...uding 2 3 15 amp fuses in the power inlet box on the back of the stove Make Up Air In sleeping rooms or in manufactured homes outside air is required Outside air or make up air may be needed in any ti...

Page 4: ...er or fan speed can not be made in the start up phase which can take between 10 to 15 minutes When the stove starts automatically in thermostat or program mode the fan speed goes to its previous setti...

Page 5: ...rnal clock Button to select operating mode MANUAL AUTOMATIC ECO STOP Hold for 5 seconds with stove off to swtich from Celsius to Farenheight Button for scrolling up or down to adjust flame power fan t...

Page 6: ...a center for the stove The panel will display the current status of the stove i e Start up or Auto The Thermostat remote control is not included on the stoves that have the LED control panel but a sma...

Page 7: ...art by going over the Emergency Panel as the Black Panel is similar but easier Some functions of the panel View the current operating status of individual components Adjust the feed rate De activate a...

Page 8: ...ontrolled by the REMOTE CONTROL OFF The stove turns off WITHOUT the aid of the remote control Also turn the selector to OFF to cancel an Alarm code MAX MED MIN SELECTOR This selector sets the power of...

Page 9: ...een in operation 000 145 145 operating hours 001 145 1145 hours With the switch at MED you can read the RPM of the combustion blower and the litre minute of fresh air that is passing through the air s...

Page 10: ...160 L min as minimum intake the combustion blower will adjust to guarantee this amount of incoming air In this case the combustion blower has a reference value of 1 600 rpm With normal installation a...

Page 11: ...the smoke fan in power 5 1900 1900 rpm Air flow during thermal shutdown 150 150 lpm Minimum value of revolutions during shutdown 2500 2500 rpm Air flow during grate cleaning 350 350 lpm Minimum value...

Page 12: ...ust Feed HOLD THE TEST BUTTON DOWN FOR 5 SECONDS The display will show 0 by pressing the right button with a sharp instrument You can increase or decrease the quantity of pellets using the following s...

Page 13: ...ustion blower runs at a fixed rate HOLD DOWN THE TEST BUTTON FOR 10 SECONDS The display will show ON Press the button to switch between ON or OFF To re set the counter or clear maintenance warnings HO...

Page 14: ...l When the stove is off turn switch to Remote position Press the button Three lines appear Press the Off On Button on the remote Three beeps from the Emergency panel indicate that the Sync was success...

Page 15: ...e connect power and switch the stove on Within the first 10 seconds while the Green Red lights flash press and hold the button Press the test button to select the correct software 01 Ego Star 02 Suite...

Page 16: ...he emergency panel combined The panel will display the current status of the stove i e Off Start up Manual Auto Auto Eco Using the 4 buttons it is very simple to scroll through the menus set the desir...

Page 17: ...oncerning the state of the stove such as The temperature of the smoke sensor The RPM of the combustion blower The liters minute detected by the flow sensor The working hours Voltage to the distributio...

Page 18: ...the Air Flow Sensor Press the button in TOP RIGHT to access the menu Scroll with the two bottom buttons until you reach the SETTINGS menu Press the button next to SET Scroll with the two bottom button...

Page 19: ...the bottom keys confirming with OK first the letter and then the number Confirm by pressing SET Scroll through the various menus to STOVE TYPE On the display the 00 appears Confirm by pressing SET Mo...

Page 20: ...nual we can identify the type of problem the stove is reporting The alarm codes start with the letter A Alarm followed by a two digit number ie A01 Stove did not light An alarm is signaled by a beepin...

Page 21: ...air could signal a blocked grate A07 The door is ajar A08 Combustion Blower broken registers 0 rpm A09 Flue Temperature sensor is broken A10 Igniter is broken A11 Feed motor or wiring to the feed mot...

Page 22: ...ensor cooled to 45 C Most likely the stove ran out of fuel A 04 Flue exceeds 200 C 392 F air or 210 C multi air this is very rare because at 180 C the stove goes to minimum feed but it can be caused b...

Page 23: ...e flow sensor The stove will run but will burn poorly especially if there is no vertical pipe Other Alarms A 07 Combustion blower working properly 40 L min air flow A 08 Combustion blower at 500 rpm A...

Page 24: ...ct the stove to the power supply through the ON OFF main switch 1 Within the next few seconds locate and press the reset button on the motherboard indicated with an arrow until a first bip is heard 2...

Page 25: ...stove is started in Auto or Auto eco mode and the set temperature is lower than ambient room temperature the stove will start up and then turn off Consult the service manual The manual is very compre...

Page 26: ...e door glass Remove the ash from the lower heat exchanger Clean all the heat exchangers and remove ash and encrustations Clean the discharge T Clean the pipe connection Replace the door seal Control a...

Page 27: ...hrough so that the dust and soot falls into the lower chamber Open the lower inspection panel under the ash pan and vacuum out the lower chamber Replace the seal gaskets on the panels to guarantee a p...

Page 28: ...ating season turn the stove off with the switch at the rear and remove the power cord from the wall Remove the batteries from the remote to avoid damaging the remote with corroded batteries Fresh batt...

Reviews: