25
www
.wittur
.com
Changes can be made without notice
PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
−
RESERVED AREA
•
Using keys
ã
and
ä
run through the menu “PROFILE SETTING” and choose the option ADVANCED SETTING
•
Using the “OK” key, confirm the option
After confirming the choice by pressing the “OK” key, a 5-code password is required on the display. The factory default access code is
00001.
Use keys
á
and
â
to move to different digits and to select the necessary coded digit use keys
ã
and
ä
; Press OK at the end.
The following options are viewed on the display:
•
OPENING PARAMETERS
•
CLOSING PARAMETERS
•
CHANGE PASSWORD
•
RESET SPEED
•
INPUT LEVELS LOGIC
•
DELAY Ra TO IREST OPENING (ONLY FOR DIGIDOOR EMULATION)
•
DELAY Lc TO IREST CLOSING (ONLY FOR DIGIDOOR EMULATION)
Using keys
ã
and
ä
run through the menu and choose the required option
•
Using the “OK” key, confirm the option
•
The following options are available:
−
“BACK”: press key F1 to restore the MAIN MENU
−
“MENU”: press key F3 to restore the MAIN MENU
7.5.1 Option “Opening Parameters”
The following options are viewed on the display:
•
LOW START SPEED
•
ACCELERATION START
•
ACCELERATION
•
HIGH SPEED
•
OFFSET DECELERATION
•
DECELERATION
•
LOW SPEED
•
FITTINGS
For each of the above listed parameter the parameter name is displayed at the top, the current value is displayed at the bottom with the
relevant unit measure; the up/down arrow keys allow changing the current value.
•
The following options are available:
−
“BACK”: press key F1 to restore the MAIN MENU
−
F2 KEY: to open and close the door, to test the modified profile
−
“DRAW”: press key F3 to update the speed profile drawing
7.5.2 Option “Closing Parameters”
The following options are viewed on the display:
•
LOW START SPEED
•
ACCELERATION START
•
ACCELERATION
•
HIGH SPEED
•
OFFSET DECELERATION
•
DECELERATION
•
LOW SPEED
•
FITTINGS
For each of the above listed parameter the parameter name is displayed at the top, the current value is displayed at the bottom with the
relevant unit measure; the up/down arrow keys allow changing the current value.
•
The following options are available:
−
“BACK”: press key F1 to restore the MAIN MENU
−
F2 KEY: to open and close the door, to test the modified profile
−
“DRAW”: press key F3 to update the speed profile drawing
7.5.3 Option “Change Password”
This option allows the user to change access passwords; input the new password as follows:
Select the desired code digit using keys
ã
and
ä
; Use keys
á
and
â
to move to different digits. Press OK at the end.
7.5.4 Option “Reset speed”
This option allows the user to change the speed at wich the controller operate the initial reset cycle.
Select the desired reset speed using keys
ã
and
ä
. Press OK at the end.
7.5.5 Option “Input levels logic”
This option allows the user to change the Input/Output levels logic, to interface correctly the main lift controller
•
On the display are viewed all the input/output signals: the user can change the logic if needed;
•
H
(High Level) means that the signal will be activate by +24V
•
L
(Low level) means that the signal will be activate by 0V
•
Using keys
ã
and
ä
select the required input/output and using
á
or
â
select the required logic (H or L)