background image

Anchor 4000 

Installer manual  

Installation and commissioning instructions  

en_A4000-Teil 2-Errichterhandbuch V2.03.docx 

2 / 7 

 

 

General 

Locks  of  the  Anchor  4000  series  have 
standard  installation  dimensions  and  can 
be  mounted  in  all  4  installation  positions 
(right,  left,  top,  bottom).  They  have  been 
designed  for  a  boltwork  with  two  blocking 
edges, i.e. for the force to be applied  only 
on only the flank of the bolt.  
 
They  are  intended  to  be  installed  in  safes 
made of metal. 
 
The 

electronic 

lock 

requires 

no 

maintenance  in  a  normal  residential  or 
office  environment.  We  recommend  a 
security  and function  test  of  the  electronic 
lock after around 10,000 closings. 
 
For security reasons it is not permissible to 
install the electronic lock in the area of the 
cutouts in the safe door.

It  is  essential  that  the  lock  is  protected 
against 

attacks 

from 

outside. 

We 

recommend that you protect against access 
the  security-relevant  parts  of  the  high-
security  lock  also  when  the  door  of  the 
container that holds the valuables is open.  
 
It is not permissible to use two locks of the 
same  type  in  connection  with  analog 
keypads 

without 

any 

additional 

components for locking state detection.  
 
Do  not  apply  any  lubricants  or  other 
substances to the lock. 

 

 

 

 

 

Always use the following sequence for installation: 

 

•Check the preconditions for installation 

•Wiring / installation of the cables

•Set up the power supply

•Function test of the locking mechanism

•Make all the settings (user system, Dualcode, inputs and outputs, delay time)

Ensure that the load limits are not exceeded at any time. 

You can find the corresponding values in Annex C "Technical data".  

 

Summary of Contents for Anchor 4000 Series

Page 1: ...neral 2 Preparation for installation 3 Installation dimensions 3 Preparation of the boltwork door 3 Installation 4 Wiring installation 5 Connection of an analog keypad 5 Connection P signal plus UART 6 Function test 6 Input of the opening code 6 Keypad test 7 System setup 7 Mount the keypad before installing the electronic lock All the keypads of the Primor series can be used Details on installing...

Page 2: ... the electronic lock in the area of the cutouts in the safe door It is essential that the lock is protected against attacks from outside We recommend that you protect against access the security relevant parts of the high security lock also when the door of the container that holds the valuables is open It is not permissible to use two locks of the same type in connection with analog keypads witho...

Page 3: ...on of the boltwork door For installation of the lock there must be three threaded holes with 5 mm screw in depth for attachment to the boltwork or within the safe door The electronic lock is to be attached with the supplied M6 or 1 4 screws or cylinder screws minimum strength class 8 8 The length of the screws must be 25 mm or more so that a minimum screw in depth of 5 mm is attained ...

Page 4: ...direction of the bolt without any play up to the edges of the strikers of the boltwork and tighten up the retaining screws The position must be selected such that the sliding striker of the boltwork runs over the entire opening path on the slanted sliding surfaces of the bolt and when fully open on the bolt head Tighten up the retaining screws so as to ensure a permanent and secure hold The screw ...

Page 5: ...e VdS approval is restricted to operation with input units of the Primor FS FL RO and RE series Connection of an analog keypad As supplied only the interface for an analog keypad from the Primor series is active If the lock is to communicate with a digital input unit i e an intelligent one then additional settings are required in the setup menu 6 in addition to the selection of the corresponding i...

Page 6: ...nction test after completing all the mounting and installation work With the door open you should open and close the lock several times using the master code that had been set at the factory The relationship between easy opening and reliable closing can be set via the operating lever of the boltwork The locking check can be done via the operating lever of the boltwork and should be performed after...

Page 7: ...s indicated by a long signal tone and the function test is terminated The system must be checked System setup The setting options and the control sequences that are required are described in the user manual We therefore recommend the following procedure Setup of the users menu 1 if applicable parameterisation of the inputs and outputs menu 6 if applicable setting up the Dualcode condition menu 6 i...

Reviews: