Appendix
SP
+
ATEX MF
en-32
2022-D014984
Revision: 07
10.6
Technical specifications
10.6.1 Technical data for SP
+
060 for use in potentially explosive atmospheres
Technical data for SP
+
060, 1-stage
Clam-
ping
hub Ø
[mm]
Ratio i
3
4
5
7
8
10
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
21
34
34
34
22
22
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
17
26
26
26
17
17
Emergency stop torque T
2Not
[Nm]
(1000 times possible during the
service life of the gearbox)
11
29
38
47
47
47
47
14 / 19
47
47
47
47
47
47
Permissible average input
speed n
1N
[min
-1
]
(At T
2N
)
a
–
1800
1850
1900
2450
2600
2600
Max. input speed n
1Max
[min
-1
]
–
4500
4500
4500
4500
4500
4500
Average no-load running
torque T
012
[Nm]
(For n
1
=3000 min
-1
and gearbox
temperature 20 °C)
b
–
0.68
0.52
0.48
0.34
0.32
0.32
Max. backlash j
t
[arcmin]
–
Standard ≤ 4 / Reduced ≤ 2
Torsional rigidity C
t21
[Nm/arcmin]
–
3.5
Max. axial force F
2AMax
[N]
c
–
1650
Max. lateral force F
2QMax
[N]
c
–
1400
Max. tilting moment M
2KMax
[Nm]
–
98
Service life L
h
[h]
–
see Chapter 7.2.4 "Replacing the gearbox"
Weight incl. standard adapter
plate m [kg]
–
1.9
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 58
Max. permissible housing
temperature [°C]
–
+80
Ambient temperature [°C]
–
see Chapter 10.4 "Specifications for startup and
Lubrication
–
synthetic gear oil (see also Chapter 7.1
Direction of rotation
–
In- and output same direction