Appendix
TP
+
ATEX
en-50
2022-D020259
Revision: 04
10.6.6 Technical data for TP
+
110 MA for use in potentially explosive atmospheres
Ordering code: TP..xxxx-xAx-xxxxx-xxx-xx
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
24
5.63
5.54
5.63
5.78
5.44
5.51
5.40
32
8.80
8.70
8.80
8.95
8.61
8.67
8.56
38
9.87
9.77
9.87
10.0
9.68
9.74
9.63
48
24.5
24.4
24.5
24.9
24.3
24.4
24.3
a
No-load running torques diminish during operation
b
Refers to the center of the output shaft or flange
Tbl-34: TP
+
110, 2–stage MF, i = 40 – 100: Technical data for use in potentially explosive atmospheres
Technical data for TP
+
110 MA, 3-stage
Ratio i
154
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
2080
Nominal output torque T
2N
[Nm]
(At n
1N
)
1225
Emergency stop torque T
2Not
[Nm]
(1000 times possible during the service life of the
gearbox)
3900
Permissible average input speed n
1N
[min
-1
]
(With T
2N
and 20 °C ambient temperature)
2800
Max. input speed n
1Max
[min
-1
]
3600
Average no-load running torque T
012
[Nm]
(For n
1
=3000 min
-1
and gearbox temperature 20 °C)
a
1.8
Max. backlash j
t
[arcmin]
≤ 1
Torsional rigidity C
t21
[Nm/arcmin]
650
Max. axial force F
2AMax
[N]
b
8040
Max. tilting moment M
2KMax
[Nm]
2400
Service life L
h
[h]
see Chapter 7.2.3 "Replacing the
Weight incl. standard adapter plate m [kg]
35.4
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
≤ 59
Max. permissible housing temperature [°C]
+80
Ambient temperature [°C]
see Chapter 10.4 "Specifications for
Technical data for TP
+
110 MF, 2-stage, i = 40 – 100
Clam-
ping
hub Ø
[mm]
Ratio i
40
50
61
64
70
91
100