Two ChronoMaster software versions are available:

ChronoMaster

ChronoMaster PRO

The 

“Witschi Token Installer”

 software can be used to install a

token on the device to extend the device to the PRO version.

Ordering the token
The token is created exactly for the device to be

extended. The token contains the item number

and the serial number of the device.
For further information, see the software

manual.

Using what is called a demo token, you can test the PRO ver-

sion for a certain time. The demo token has a timestamp and

can only be installed once on the device. If new functions are

provided by the manufacturer, a new demo token can be cre-

ated, which can be installed again once.

A USB cable is used to connect the ChronoMaster to the PC or

tablet computer. The measurements are controlled using the

corresponding 

“Chronoscope Service”

 display software.

In the 

“Chronoscope Service”

 display software, you can

choose between the 

“Diagram”

 and 

“Vario”

 display modes

for both versions. In addition, the 

“Trace”

“Sequence”

,

“Polar”

“Scope 1”

 and 

“Scope 2”

 display modes are

included for the ChronoMaster PRO version.

Information on controlling the measurements
Further information on controlling the measure-

ments is to be found under 

Ä

 “Display modes”

on page 9, in 

Ä

 Chapter 4 “Performing a

measurement” on page 21 and in the corre-

sponding software manual.

Versions

Controlling the measurements

 

  

 

01.09.2020

Precision measuring device ChronoMaster

7

Summary of Contents for 13.3210

Page 1: ...Precision measuring device ChronoMaster Operating instructions Read the instructions prior to performing any task...

Page 2: ...instructions 2017 Witschi Electronic AG Witschi Electronic Ltd Bahnhofstrasse 26 3294 B ren a A Switzerland Telephone 41 32 352 05 00 Fax 41 32 351 32 92 Email welcome witschi com Internet www witsch...

Page 3: ...basic understanding and may deviate from the actual design The content of this document is protected by copyright It may be used within the context of using the ChronoMaster No other use is permitted...

Page 4: ...asurement settings 21 4 2 Positioning the watch and starting a measure ment automatically 21 4 3 Controlling the measurement using control keys 25 4 4 Monitoring and configuring the measurement 26 5 T...

Page 5: ...t automatically on page 21 3 Clamping jaw made of neoprene for clamping the watch or the clockwork Chapter 4 2 Positioning the watch and starting a measurement automatically on page 21 4 USB cable for...

Page 6: ...umbers can be determined automatically The manual adjustment for any beat numbers in a range between 3 600 and 72 000 A H is possible as an alternative Watches can be tested in the 6 main testing posi...

Page 7: ...rer a new demo token can be cre ated which can be installed again once A USB cable is used to connect the ChronoMaster to the PC or tablet computer The measurements are controlled using the correspond...

Page 8: ...scope of delivery also includes This document Calibration certificate Warranty information Dust cover 1 3 Software The measurements are controlled using the Chronoscope Service display software It is...

Page 9: ...ype of the watch that is to be tested by consulting the watch manufacturer Information in the software manual Further information on the measuring modes is to be found in the corresponding software ma...

Page 10: ...n be selected 0 4 Numerical display in degrees Lift angle adjustable from 10 to 90 resolu tion 0 1 Beat error 9 9 ms 0 1 ms 0 1 ms Numerical display in milliseconds Designation Purpose USB Connect dev...

Page 11: ...AM at least 4 GB USB interface 2 0 type A Display Minimum resolution 1366 x 768 pixels Data Value Unit Temperature range 10 50 C Relative humidity maximum 10 80 non con densing Recommended requirement...

Page 12: ...tially hazardous situation that can entail material damage if not avoided ENVIRONMENT This combination of symbol and signal word indicates possible hazards to the environment This symbol draws your at...

Page 13: ...the device NOTICE Material damage due to opening the housing Opening the housing poses a risk of damaging components inside the ChronoMaster or of damaging the housing itself Never open the housing y...

Page 14: ...ional health and safety and environmental protection requirements that apply to the device s area of application The following applies in particular Throughout the entire period that the device is in...

Page 15: ...dition the operator has been instructed by the owner about the tasks entrusted to him or her and about possible hazards in the event of improper behaviour The operator may only perform tasks that go b...

Page 16: ...the delivery 2 Make a note of the scope of damage on the carrier s delivery note 3 Lodge a complaint Claims for damages can only be made within the applicable claim periods Lodge a complaint for any...

Page 17: ...up the device in a low noise environ ment Do no set up the device in the direct prox imity of electromagnetic radiation e g as caused by mobile telephones NOTICE Risk of material damage due to unsuit...

Page 18: ...tor rights are required for the PC or tablet computer Further information on the software is to be found in the corresponding software manual Personnel Operator 1 Connect the USB flash drive to the US...

Page 19: ...the installation Fig 4 Software updates Information on possible software updates is provided on the manufacturer s website Fig 4 Installing the software 01 09 2020 Precision measuring device ChronoMa...

Page 20: ...ter 2 Plug the USB plug of the USB cable Fig 6 1 into the USB port of the PC or tablet computer Fig 6 2 Fig 6 Connecting the ChronoMaster The ChronoMaster is connected to the PC or tablet computer The...

Page 21: ...settings It is also possible for you to create your own programs with frequently used measurement settings Information in the software manual Information on selecting and setting the pro grams is to b...

Page 22: ...g 8 1 outwards and hold it 2 Place the watch or cup on the clamping area so that the crown of the watch or cup is positioned against the signal sensor Fig 9 1 Fig 10 1 Clamp the complete watch or cloc...

Page 23: ...ng process starts automatically Fig 12 Alternatively the measurement can be started via the Restart button in the display software Information in the software manual Information on the measuring proce...

Page 24: ...guide the clamping jaw Fig 15 1 to the clock work The clockwork without housing is clamped The LED on the ChronoMaster Fig 15 2 flashes at the same frequency as the watch beats The measuring process...

Page 25: ...he following functions are assigned to the control keys No Function 1 Program selection select next lower program 2 Program selection select next higher program 3 Restart current measurement 4 Pause c...

Page 26: ...ent and the measurement results Setting the signal strength Pausing and resuming the measurement Printing the measurement results Creating screenshots Restarting a measurement Information in the softw...

Page 27: ...ablet computer Fig 18 2 5 2 Transportation and storage of the ChronoMaster NOTICE Risk of material damage due to improper trans port In the event of improper transport the device may fall or topple Th...

Page 28: ...to any aggressive media Protect the device from sunlight Protect the device from mechanical vibra tions Store the device at a temperature between 20 C and 70 C Store the device at a relative humidity...

Page 29: ...work for maintenance or cleaning disconnect the USB cable from the PC or tablet computer Keep moisture away from live parts 6 2 Maintenance schedule Interval Maintenance work Personnel Daily Clean the...

Page 30: ...ce If there is any visible external damage proceed as follows 1 Shut down the ChronoMaster Chapter 5 1 Shutting down the ChronoMaster on page 27 2 Contact Customer Service Customer Service on page 3 7...

Page 31: ...rrect disposal may result in hazards to the environment Do not dispose of the device along with the household waste Hand over the device to a municipal collection point or have it disposed of by a spe...

Page 32: ...ble 13 Danger due to electric current 29 due to misuse 14 to the environment 31 Delivery 16 Demo token 7 Device cleaning 29 Commissioning 16 connecting 20 disposal 31 maintenance 29 Measuring options...

Page 33: ...3 Operating conditions 11 Operator 15 Original packaging 16 27 28 Owner 14 Owner s obligations 14 P Personnel qualifications 15 Power supply 13 PRO version 7 Product description 5 Program 21 Program s...

Page 34: ...16 Unsuitable location 17 USB cable 5 connecting 20 USB flash drive 8 USB port 10 V Versions 7 W Watch clamping 21 positioning 21 Witschi Token Installer 7 01 09 2020 Precision measuring device Chron...

Page 35: ...Appendix 01 09 2020 Precision measuring device ChronoMaster 35...

Page 36: ...A Declaration of conformity 01 09 2020 Precision measuring device ChronoMaster 36...

Page 37: ......

Reviews: