WS CIRCULATING PUMP DELTA TWP 15

ASSEMBLY

Installation

The circulating pump is installed in the pipeline and as a rule, direct-
ly upstream of the service water reservoir in such a way that the water 
from the last tap is pumped back to the reservoir through the circulating 
pipeline. A check valve must be installed on the pump‘s discharge side 
(primary side) to prevent pump backflow when the tap is opened. A shut-
off valve is installed on the pump‘s inlet side  (secondary side) to make 
servicing easier. Assemble the pump with the horizontally positioned pump 
motor when the power is shut off (the arrow on the pump housing shows 
the direction of flow). Ensure when performing the heat insulation work 
that the pump motor and the electronic housing are not insulated.

Electrical connection

All of the Delta TWP 15 series pumps are intended for a 230 V AC / 
50 Hz connection. The pumps do not require a motor circuit-breaker.

Startup

The system must be thoroughly flushed before the pump is started up to 
prevent contaminants or foreign bodies from remaining in the system. The 
system must then be thoroughly vented. The pump‘s union nut must be 
slightly loosened for this to allow the air to escape from the pump. The 
supply line is then carefully opened until water leaks out on the pump. 
Please ensure that the electrical connection is protected against water and 
moisture. It is recommended that the pump be deactivated for this.
A suitable tool is then used to tighten the union nut and the pump can 
be started up. Audible flow noises indicate that air is present in the pipe 
system. This process may need to be repeated and in any case, the pump 
must be prevented from running dry for prolonged periods.

15_05_Pumpe_Delta_TWP_WS_Betriebsanleitung.indd   16

05.05.15   14:52

Summary of Contents for WS DELTA TWP 15

Page 1: ...15 english fran ais deutsch SEITE 2 11 PAGE 12 21 PAGE 22 31 Einbau und Betriebsanleitung Installation and Operating Instructions Notice de montage et d utilisation 15_05_Pumpe_Delta_TWP_WS_Betriebsa...

Page 2: ...Technische Daten Delta TWP 4 5 Pumpeneinstellungen 5 Bedienung Leuchtfeld 5 Montage 6 8 Einbau Elektrischer Anschluss Inbetriebnahme 6 7 Kennzeichnung von Hinweisen 7 Personalqualifikation 7 Sicherhe...

Page 3: ...chtlinie 2004 108 EG EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Niederspannungsrichtlinie 2006 95 EG EN 60335 1 2012 EN 60335 2...

Page 4: ...ruck max 65 C Wassertemperatur Leistung 2 5 8 Watt niroummantelter Rotor Laufrad aus Technopolymer Anwendung Die Brauchwasserpumpe wird zur Zirkulation in Ein und Zweifamilienh u sern mit einer Leitun...

Page 5: ...itung ist eine Kopie der EG Konformit tserkl rung beigef gt Bei einer mit uns nicht abgestimmten nderung verliert diese ihre G ltigkeit Bedienung Das Display leuchtet sobald die Pumpe an die Versorgun...

Page 6: ...e Flussrichtung an Bei W rmed mmarbeiten darauf achten dass der Pumpenmotor und das Elektronikgeh use nicht ged mmt werden Elektrischer Anschluss Alle Pumpen der Baureihe Delta TWP 15 sind f r den Ans...

Page 7: ...henden Vorschriften zur Unfallverh tung sind zu beachten Warnung Gefahr durch elektrische Spannung Gef hrdungen durch elektrische Energie sind auszuschlie en Weisungen lokaler oder genereller Vorschri...

Page 8: ......

Page 9: ...rsagen vorgeschriebener Reparatur und Wartungsarbeiten Sicherheitsbewusstes Arbeiten Die in dieser Anleitung aufgef hrten Sicherheitshinweise und auch die bestehenden nationalen Unfallverh tungsvorsch...

Page 10: ...tung mit dem Produkt vertraut gemacht haben Arbeiten an der Pumpe sind grunds tzlich nur im Stillstand der Anlage zul ssig Vorgeschriebene Vorgehensweisen zum Stillsetzen sind gegebenenfalls aus der B...

Page 11: ...WS ZIRKULATIONSPUMPE DELTA TWP 15 11 NOTIZEN deutsch 15_05_Pumpe_Delta_TWP_WS_Betriebsanleitung indd 11 05 05 15 14 52...

Page 12: ...chnical data Delta TWP 14 15 Pump settings 15 Operation luminous field 15 Assembly 16 18 Installation Electrical connection Commission 16 17 Labelling of instructions 17 Personnel qualifications 17 Sa...

Page 13: ...Directive 2004 108 EG EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Low Voltage Guideline 2006 95 EG EN 60335 1 2012 EN 60335 2 51...

Page 14: ...ng pressure Characteristic curve Max 65 C water temperature Output 2 5 8 Watt Stainless steel encased Rotor Technopolymer impeller Application The service water pump is used for circulation in single...

Page 15: ...r sections This manual includes a copy of the EC Declaration of Conformity It loses its validity if a change is made which has not been approved by us Operation This display lights up as soon as the p...

Page 16: ...ction All of the Delta TWP 15 series pumps are intended for a 230 V AC 50 Hz connection The pumps do not require a motor circuit breaker Startup The system must be thoroughly flushed before the pump i...

Page 17: ...ruled out Instructions of local or general regulations e g IEC VDE etc and of the local power utility must be complied with Personnel qualifications The personnel for the assembly operation and mainte...

Page 18: ......

Page 19: ...to the discharge of fluids when a leak occurs Failure of required repair a d ai te a ce work Working with an awareness of safety The safety i structio s provided i this a ual a d the existi g atio al...

Page 20: ...amiliarise themselves with the product Work on the pump is generally only permitted when the sys tem is shut down The specified procedure for shutting down the system can be found in the operating man...

Page 21: ...WS CIRCULATING PUMP DELTA TWP 15 21 NOTES english 15_05_Pumpe_Delta_TWP_WS_Betriebsanleitung indd 21 05 05 15 14 52...

Page 22: ...chniques Delta TWP 24 25 R glages de la pompe 25 Utilisatio Cha p lu i eux 25 Montage 26 28 Installation Raccordement lectrique Mise en service 26 27 Marquage des remarques 27 Qualification du personn...

Page 23: ...ibilit lectromagn tique 2004 108 CE EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Directive basse tension 2006 95 CE EN 60335 1 20...

Page 24: ...rature d eau ax 65 C Puissa ce 2 5 8 Watt Rotor e velopp d i ox Roue e tech opoly re Application La pompe eau sanitaire est utilis e pour la circulation dans les maisons i dividuelles et ju el es avec...

Page 25: ...t CE est jointe ces instructions Celle ci est annul e en cas de modification non autoris e par nos soins Utilisation L cra s allu ed squelapo peestraccord e late sio d ali e tatio La commande One Touc...

Page 26: ...po pe i dique le se s d coule e t Lors de travaux d isolatio ther ique veiller e pas isoler le oteur de la po pe et le bo tier lectro ique Raccordement lectrique Toutes les pompes de la gamme Delta T...

Page 27: ...e Respecter les pr sentes instructions pour la pr vention des accidents Avertissement Risque li la tension lectrique Exclure les da gers li s l ergie lectrique Respecter les consignes des prescription...

Page 28: ......

Page 29: ...a ce des travaux de r paratio et de ai te a ce prescrits Comportement respectueux de la s curit Les consignes de s curit indiqu es dans les pr sentes instructions ainsi que les prescriptions nationale...

Page 30: ...satio De a i re g rale les travaux sur la po pe so t u ique e t autoris s lorsque l i stallatio est l arr t Les i struc tio s d utilisatio four isse t gale e t la proc dure prescrite pour l arr t Apr...

Page 31: ...POMPE DE CIRCULATION WS DELTA TWP 15 31 fran ais NOTES 15_05_Pumpe_Delta_TWP_WS_Betriebsanleitung indd 31 05 05 15 14 52...

Page 32: ...WS Weinmann und Schanz GmbH Rote L nder 4 72336 Balingen Deutschland www weinmann schanz de STAND 05 15 15_05_Pumpe_Delta_TWP_WS_Betriebsanleitung indd 1 05 05 15 14 52...

Reviews: