1.1 Pump Applications
The deep well electric pumps (hereinafter referred to as the “electric pumps”) include SA(m) series electric pumps. This
series of electric pumps are with high head due to its multistage impellers structure, which are widely used in irrigation,
deep well water lifting, tower water delivery, urban construction, and water supply to industrial and mining enterprises.
1.2 Pump Introduction
SA(m) series are oil-filled being composed of two parts i.e. pump body and motor. Pump body is with multistage centrifugal
impellers lying upper of the Electric pump, a single-phase or three-phase asynchronous motor is at the bottom of the
Electric pump; adopting single-ended mechanical seal as dynamic seal in the motor, and at the place of sealing of each
fixed spigot is an O-shaped rubber seal ring used as the static seal.
1. Product Information
1.3 Pump Nameplate
The pump nameplate are located on the terminal box of the pump. The information and data on the pump nameplate are
described as follows.
WATER PUMP
Model
ແ
/PLQ
4PD[
/PLQ
P
+PD[
P
&¦)
,&/
+]
9
N:
+3
$
,3
1:
'LVFKDUJH
5RWDWLRQ
NJ
,Q
1R
USP
ໂ
່
໊
ໍ
໎
໐
໓
ໃ
ໆ
ໄ
້
໑
໔
໒
໌
໋
21
Pos.
Description
1
Pump model
2
Flow range
3
4
5
Rated voltage
6
Rated current
7
Head range
8
9
10
Rated speed
11
Maximum flow
12
Maximun head
13
Output power in kW
14
Output power in HP
15
Netto weight
16
Discharge connection size
17
Frequency
18
Insulation class
19
Product serial number
20
Capacitance in µF
21
IP code
1.4 Operating Conditions
The electric pump shall be able to operate continuously and normally under the following operating conditions:
1. The temperature of the medium does not exceed 40°C
2. The pH value of the medium is 6.5~8.5
3. The mass ratio of the solid impurities contained is not more than 0.01% and the particle size is not bigger than 0.2mm
4. The submersible depth of the electric pump in the water is 5~70m
5. A
ccording to DIN VDE 0100, a submersible motor pump may only be used outdoors if the pump is equipped
with 10m connection cable without intermediate connection. For submersible pumps used for construction sites
and garden ponds, H07.... type cable is necessary.
Table 1: Pump nameplate data
Summary of Contents for ADELINO 2.5SAm
Page 38: ...Installations und Betriebsanleitung 01...
Page 67: ...Installation and operation instructions 24 Appendix 9 S 9 S 9 S 9 S...
Page 73: ...Installation and operation instructions 30 Appendix 6SA T Deep Well Pump A A A A...
Page 74: ...Installation and operation instructions 31 Appendix 6SA S Deep Well Pump A A A A...
Page 75: ...Installation and operation instructions 32 Appendix A A A...
Page 76: ...Installation and operation instructions 01...
Page 114: ...IInstrukcja monta u i obs ugi 01...