![WiT WT901BLECL 5.0 Manual Download Page 21](http://html1.mh-extra.com/html/wit/wt901blecl-5-0/wt901blecl-5-0_manual_989787021.webp)
https://wiki.wit-motion.com/english
Wh86 13652339539 E-mail:[email protected] Web:https://wiki.wit-motion.com/english
- 21 -
0x00
:
Analog input
(
default
)
0x01
:
Digital input
0x02
:
Output digital high level
0x03
:
Output digital low level
Set Port D1
FF AA 0F D1MODE 00
Set port D1
D1MODE
:
D1
0x00
:
Analog input
(
default
)
0x01
:
Digital input
0x02
:
Output digital high level
0x03
:
Output digital low level
Set Port D2
FF AA 10 D2MODE 00
Set port D2
D2MODE
:
D2
0x00
:
Analog input
(
default
)
0x01
:
Digital input
0x02
:
Output digital high level
0x03
:
Output digital low level
Set Port D3
FF AA 11 D3MODE 00
Set port D3
D3MODE
:
D3
0x00
:
Analog input
(
default
)
0x01
:
Digital input
0x02
:
Output digital high level
0x03
:
Output digital low level
Note: After the above settings are completed, you must send a save command to save.
6.3 Register address
Address
Symbol
Mean
0x00
SAVE
Save current configuration
0x01
CALSW
Calibration
0x02
KEEP
0x03
RATE
Return rate