Wisperkool 20 ton Installation And Service Manual Download Page 2

20 TON

2

Custom HVAC & Filtration    726 Seneca Place    Madison, WI 53711    608-334-5999   [email protected]  Jan 2016

This manual addresses the 

20 ton wisperkool™HVAC

 unit 

for temporary cooling and heating solutions.  This manual includes 
technical information, start-up information, and unit maintenance.

The information contained in this manual is provided to ensure 
the safe installation and operation of the equipment.  It is for 
reference only.

LIVE ELECTRICAL COMPONENTS!

During installation, testing, servicing and troubleshooting of this product, it may 
be necessary to work with live electrical components.  A qualified licensed elec-
trician or other individual who has been properly trained in handling live electri-
cal components must perform these tasks.  Failure to follow all electrical safety 
precautions when exposed to live electrical components could result in serious 
injury or death.

FAILURE TO FOLLOW STATE AND LOCAL CODES 

COULD RESULT IN DEATH OR SERIOUS INJURY. 

All vertical HVAC units should be installed per the National 
Electric Code(NEC) and/or applicable state and local codes.

Summary of Contents for 20 ton

Page 1: ...e Vertical Air Conditioning and Heating Systems Custom HVAC Filtration 726 Seneca Place Madison WI 53711 608 334 5999 jeff wisperkool com Jan 2016 Installation and Service Manual for 20 Ton Units 82 8...

Page 2: ...LECTRICAL COMPONENTS During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components A qualified licensed elec trician or other in...

Page 3: ...ty 3 Size 20 in Evaporator Coil Rows 4 Face Area 12 5 sq ft FPI 10 Condenser Coil Rows 4 Face Area 21 sq ft FPI 14 Filter Type Disposable Quantity 3 Dimensions 24in x 24 in x 2 in General Information...

Page 4: ...Note Capacities are gross values and are not adjusted for motor heat Electric Heat Air Temperature Rise Heater kW Total MBH Temperature Rise F 45 153 5 17 7 Note Air temperature rise kW x 3413 scfm x...

Page 5: ...WI 53711 608 334 5999 jeff wisperkool com Jan 2016 Fork Lift Pockets Warning Heavy Objects Use a forklift of suitable capacity to move the unit Failure to properly lift unit could result in death or...

Page 6: ...sed When connecting multiple units in series do not exceed amp rating of cable used Exceeding amp ratings could cause permanent damage to the electrical cables Electrical Information Circuit Breaker Y...

Page 7: ...WI 53711 608 334 5999 jeff wisperkool com Jan 2016 44 Side Back 81 82 82 82 81 44 82 81 44 Front with Duct Kit Side with Duct Kit Front Side 82 Line Drawings Blower Access Panel Electrical Access Pane...

Page 8: ...oosen Tent clamps on top and sides of unit Carefully slide the sidewall fabric under the tent clamps on each side and top of the unit Tighten down the tent clamps using a 3 4 inch wrench or socket DO...

Page 9: ...de at 72o based on the inside temperature at LOW FAN speed 5 Touch the thickest vertical bar above the screen again to run the machine at HIGH FAN speed 6 A yellow screen indicates that the machine is...

Page 10: ...racket Retighten the 4 bolts holding the motor to the motor mount A properly tensioned belt has approximately 1 in to 1 1 2 in movement when both legs of the belt are pressed in midway between the pul...

Reviews: