Line
Neutral
Connect the Line (Black) and Neutral (White) wires from the device
with the external mains supply wires using wire connectors and
terminate the same inside the junction box.
2.
Press and hold the spring clips (on both sides of the device) and
insert the sensor into the mounting hole. Release the spring clips so
that the sensor will fit in and remain intact.
3.
To remove the sensor
from the ceiling,
hold and pull the
sensor down
Rotate the lens clockwise to
connect to the case and rotate
anti-clockwise to dismantle
from the case
Note
Note
3
3
1
&
2
4
2
Removing Lens
Position the sensor mounting base to fix and take out the mains wire through the hole
given at the mounting base.
Mount the base on the selected position using screws
To power the sensor, connect the AC Line and Neutral wires from the
mains supply to the sensor Line (Black) and Neutral (White) wires using
wire connector. Terminate the wires within the sensor mount.
Connect the sensor unit case with the Mount base (that is already fixed
in step 2) by rotating the case clockwise.
To remove the sensor unit case from the mount
base, apply pressure towards ceiling and rotate the
sensor case anti-clockwise.
SURFACE MOUNT
Mounting sensor on false ceiling
1.
2.
3.
4.
WIRING DIAGRAM
Head:
CSK Slotted
Length
38mm
8.3mm
3.7mm
Head Diameter
Screw Diameter
Rotate the lens clockwise to connect to the case