- 8 -
Connection
Plug the handset into socket "RJ-11". Connect the supply voltage.
Parameter menu
keys
— Select parameter.
key
— Open parameter sub-menu.
key
— Back.
Parameter sub-menu
keys
— Select display or value to be changed.
Cursor stands under the value, e.g. 89
keys
— Change the value.
Left
Right
Down
Up
W
I SI VX24
1. 00
V
Parameter settings with handset (Accessory)
Operation steps
Display/sub-menu
Settings
Downstream
Downstream
Select with
keys and confirm with
.
Upstream
Upstream
Upstream menu is available only if
Sys. Settings
Sys. Settings
VX 27A is plugged in.
An asterisk
(*)
in the settings shows that a setting has been changed.
Downstream
Input Equalizer
Input Equalizer
0 dB... 15 dB. 0,5 dB steps.
Input Attenuator
Input Attenuator
0 dB... 15 dB. 0,5 dB steps.
Interstage Attenuator
Interstage Att.
0 / 5 dB
Interstage slope
Interstage slope
0 / 7 dB
Upstream
Up. Attenuation
Up. Attenuation
0 dB... 30 dB. 1 dB steps.
Up attenuation <4 dB adjustable, when Interstage slope or Interstage -Att. are set in downstream menu.
Up. Slope
Up. Slope
0 dB... 10 dB. 0,5 dB steps.
Ingress Controll
ICS
Up. ICS
Switch
Low
0 dB
Pad
8 dB
High >45 dB (off)
Sys. Settings
The parameters of an VX 2...which has been set can be saved to the memory of the handset OK 41A and
transferred from there to other VX 2... systems.
Settings
Select: Save or Restore,
Yes or No
– Save
Save Val. > OK41A
yes, save
– no, not save
– Restore
Res. Val. < OK41A
yes, restore
– no, not restore
Savings
Save
Save data to EEPROM
Press
several times until the display shows:
"Save Data to EEPROM“.
07.06