background image

 

 

 

Operation Manual

 

OT 32 (Dual-) DVB-Scrambler  

 

 

 
 
 
 

 

044 137 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for OT 32

Page 1: ...Operation Manual OT 32 Dual DVB Scrambler 044 137...

Page 2: ...5 ASI IO Status Page 11 3 6 Misc Settings Page 12 3 7 ECMG Settings Page 13 3 8 ECMG Status Page 14 3 9 EMMG Settings Page 14 3 10 Detailed EMMG Status Page 15 3 11 EIS Settings Page 16 3 12 Detailed...

Page 3: ...l the unit directly above or in the vicinity of radiators or heating systems where it would be subjected to thermal radiation or oil vapours Ventilation slots Do not cover the ventilation slots Moistu...

Page 4: ...nctions z Stand alone Scrambler for DVB transport stream signals z Scrambling to selected programs or transport stream SPTS MPTS z Injecting of ECM and EMM from the CAS system into the transportstream...

Page 5: ...ASI FUSE T2A 250 VAC OFF ON P O W E R Ethernet ASI in 6 7 8 230 VAC ASI trough ASI out 1 ASI out 2 Ethernet ASI in 10 11 ASI trough ASI out 1 ASI out 2 9 Figure 2 1 Stand alone scrambler back panel in...

Page 6: ...nd IP address However its not necessary to compute the IP address to configure the scrambler first time The scrambler supports a proprietary interface called BCMD interface that allows configuration u...

Page 7: ...ified by the MAC address 00 11 to 172 29 0 130 scrcmd mac 00 11 22 33 44 55 ip 172 29 0 130 mask 255 255 0 0 reboot Identify the physical scrambler visually by its MAC address The command causes the s...

Page 8: ...ace It will automatically show if you access the scrambler or if you click on Status This page shows version numbers and an overall description of the scrambler status The example below shows the scra...

Page 9: ...al numbers Starting with 0x and decimal numbers in numeric data fields Numeric input fields are for example used to define port numbers Acceptable numbers are for example 0x201 513 0xFFFFFF00 The scra...

Page 10: ...ambler in an erroneous state because there is no transport stream present on the ASI input connector The Status page contains links that lead to status pages of some functional units of the scrambler...

Page 11: ...ty INFO informational ERROR error condition The functional unit of the scrambler that caused the event A message describing the event The Detailed Event Log consists of multiple pages You navigate thi...

Page 12: ...Number of times the input fifo of the scrambler overflowed Input null packet rate Number of null transport stream packets PID 0x1FFF per second arriving on the ASI input Queued inserted packet rate Nu...

Page 13: ...M SS You have to set the current date and time only if you plan to use activation times in Scrambling Control Groups Protocol Version Selects the ECMG protocol to be used 2 or 3 Default CP Duration Th...

Page 14: ...ttached If one is connected only you are running your system with one CAS and without backup If you have eight ECMGs attached you are running your system with four CAS and one backup for every CAS Eve...

Page 15: ...e scrambler and ECMG agreed on using See the DVB SimulCrypt specification for a detailed description of the meaning of each parameter 3 9 EMMG Settings Page The scrambler is capable of being connected...

Page 16: ...o a physical transport stream being attached to the scrambler at the desired rate It s the responsibility of the headend administrator to ensure that there are enough null packets in the transportstre...

Page 17: ...Page The EIS is an external software component that defines Scrambling Control Groups It connects to the scrambler using TCP IP The scrambler will listen on the specific port for message of the EIS If...

Page 18: ...in the menu bar 3 12 Detailed EIS Status Page The EIS status page lets you check the communication between the EIS and the scrambler 3 13 Private PSI CAT PMT Data Page The scrambler inserts private P...

Page 19: ...administrator to define PID ranges to be used for placing ECM and EMM PID s The scrambler supports up to 4 ECM generators and up to 256 Scrambling Control Groups Therefore the scrambler needs up to 10...

Page 20: ...e page will be update automatically every 5 seconds and notify you about the scanning progress If the web browser does not automatically update the page every 5 seconds you have to manually click on S...

Page 21: ...ason of the failure If everything works well the scrambler will present a list of services like shown in the example below Please note Scanning is an important process because in the case of a success...

Page 22: ...es in the menu bar or on the here link to get to the Services page Its not possible to define Scrambling Control Groups before you successful scanned a transponder If there are services scanned but no...

Page 23: ...time indicates that the SCG is currently active does scramble content The date time in addition to active indicates the activation time when the scrambling started You may click on the active codewor...

Page 24: ...fined by the EIS or SCG s defined manually by the web browser interface Although both kinds of Scrambling Control Groups are handled the same way the name of SCG s provisioned by the EIS begins with E...

Page 25: ...MM SS Until this time the SCG will be marked as pending in the Scrambling Control Group List If you leave this field empty no activation time will be defined and the Scrambling Control Group will be a...

Page 26: ...would check all component check boxes of the service If you want to scramble single components only uncheck the box left to the service name and check the appropriate boxes to the left of the componen...

Page 27: ...CG you just have to clear all contents of all access criteria input fields and then click on the Submit button You may enter an activation time to schedule the deprovisioning in the future After proce...

Page 28: ...the reboot However if you are using the Activation time feature of the scrambler you have to manually adjust the current date time after a reboot in the Misc Settings to setup the exact date time 3 23...

Page 29: ...munications GmbH Co KG Click on the button to destroy all temporary unsaved changes and reboot the scrambler using the settings currently stored in the flash memory All changes made since the last reb...

Page 30: ...z Deterministic Jitter 10 Random Jitter 8 Control Interface 100Base T Ethernet Userinterface 1 Web based Userinterface 2 Command Line Monitoring and Alarm SNMPv2c Applicable standards ETSI TR 102 035...

Page 31: ...Operation Manual 12 07 WISI Communications GmbH Co KG Page 30 of 32 12 0 V 8 500 mA DC max Power consumption W Operating temperatur range 5 C to 45 C Nominal temperatur range 15 C to 35 C...

Page 32: ...Modifications reserved WISI cannot be held liable for any printing error a link to the future Phone 49 7233 66 280 Fax 66 350 http www wisi de P O BOX 1220 75219 Niefern Oeschelbronn Germany Empfangs...