Operating instructions

WISI COMPACT

 HEADEND

OK 79T

Digital terrestrial channel converter "Free-To-Air"

„

Reception of a DVB-T signal and processing into an

analog TV channel

„

Input- /output frequency

49-862 MHz /  45-862 MHz

„

Demultiplexing and decoding of MPEG-2 signals

„

Insertion of Teletext, VPS, WSS data EN 301775

„

Decoder socket

„

All settings with OK 41 / OK 41A handset

Input

Frequency  range

49 - 862 MHz

Frequency tuning steps

500 kHz

Input impedance

75 

Return loss

> 8 dB

Level

24 - 89 dBµV

QAM 64  7/8

40 dBµV

QPSK

24 dBµV

OFDM spectrum (autom.)

2k and 8k

Type of modulation

QPSK, 16, 64 QAM

Protection  intervall

1/32, 1/16, 1/8, 1/4 (autom.)

FEC  inner  code

1/2, 2/3, 3/4, 5/6, 7/8 (autom.)

Channel  bandwidth

6, 7, 8 MHz

Video decoder

ISO 13818-2

MPEG 2 (MP@ML)

Video format

4:3 / 16:9

Video  standard (selectable)

PAL / SECAM / NTSC-M

Video level

1 Vp-p / 75 

Audio decoder

ISO 13818-3

MPEG (L1 / L2)

Audio format

Mono / Stereo / 2nd sc

Audio format switch over

Manuell / Auto

(if provider supports)

Output

Frequency  range

45 - 862 MHz

Frequency tuning steps

250 kHz

Level

88 - 98 dBµV

TV  standard

B/G, D/K, I, L, M

S/N video (CCIR-rec.567-1)

typ.56 dB, min.53 dB

Distorsion

typ 1%, max. 2%

General specifications

RF inputs and outputs connectors

F-type / 75 ohms

Operating  voltage

12 VDC / 480 mA

5 VDC / 600 mA

30 VDC / 5 mA

Power  consumption

< 8,8 W

Dimensions

45 x 250 x 170 mm

Ambient temperature range

0°C up to +55°C

Storage temperature range

-25°C up to +75°C

Max. humidity non condens.

95 %

EMV

EN 50083-2

Specifications

WILHELM SIHN JR. GmbH & Co. KG

Empfangs- und Verteiltechnik
P.O. BOX 1220,  75219 Niefern-Oeschelbronn, Germany
Phone  +49 7233  66 280, Fax - 66 350,  http://www.wisi.de

Technische Änderungen vorbehalten
Technical modifications reserved

1 Audio L input
2 Audio L output
3 Audio R input
4 Video output

5 Audio R output
6 Ground
7 Video input
8 n.c.

Remove mains plug before attaching provided cable 

(A)

flashes:

Operating

lights:

Programming mode via OK 41

Break out housing 

(1)

. Screw on cover plate and F connector

cable 

(A)

.

Tighten module

Mounting

(1)

(A)

F

IEC

F

IEC

(A)

Note: 

Upgrade OK 40A to software version >2.20!

1

2

3

5

8

6

7

4

... a link to the future