Wisi OA 13 A Mounting Instruction Download Page 2

WARNINGS

We strongly encourage you to read this manual before installation and use 
of the product and strictly observe the recommendation hereof.

Installation shall be carried out by qualified personnel. Mounting in

-

struction has to be carefully observed.

For installation and use, please observe all specific regulation and 

laws applicable in the destination country.

Carefully read all safety regulations. Failure to observe the indica

-

tions reported, can cause serious damages to third parties.

If not otherwise indicated, for tightening of screws, bolts and in gen

-

eral threaded rods, refer to applicable figures reported in Tab. 2 in the 

paragraph  General Installation Instructions for GIBERTINI Antennas

Gibertini srl reserve the right to change specifications to products and to documentations without prior notice.

NOTES ABOUT DISPOSAL 

The barred bin symbol indicates that the product must be disposed of separately from other waste 

and cannot be thrown into the domestic waste at the end of its life. The user will therefore take the 

appliance at the end of its life to the suitable separated collection centres for metal parts waste in 

their own town. An adequate separated collection for sending of the appliance to recycling, treat

-

ment and environmentally compatible disposal helps to avoid possible negative effects on the environment 

and on health thus favouring the reuse and recycle of the materials of which the appliance is made of. The 

unauthorised disposal of the product by the user causes the application of administrative fees provided for 

by the regulation in force.

TechNIcAl SpecIfIcATIoNS

OA 13 A

Frequency range (GHz)

10.00 - 13.00

Feed illumination angle

70°

Outside dimension (cm)

124.5 x 133.5

Feeder clamp (mm)

40 / 23

Reflecting dimension (cm)

121.0 x 130.0

Elevation angle

0° - 90°

Illumination efficiency * (%)

70

Mast clamp (mm)

55 - 100

Gain * @ 10.70 GHz (dBi)

 41.1

Alu reflector thickness (mm)

1.5

Gain * @ 11.70 GHz (dBi)

 41.9

Steel  reflector thickness (mm)

1.0

Gain * @ 12.75 GHz (dBi)

 42.6

Antenna net weight (kg.)

alu 16,50

Cross polarization * on axis (dBc)

 - 28

steel 21,20

First side lobe level * (dBc)

- 24

Wind load @ 120 km/h (kg) [worst-case]

162

Noise temp. * @ 12GHz, 36° elevation (K)

34

Working temperature

- 30° / + 70°

F/D  radio

0.66

Humidity

0 – 100%

3dB Beam width* @ 11.7GHz

1.32°

Offset pointing angle

21.3°

* matched feed | Data subject to change without notice | Additional information available upon request

Summary of Contents for OA 13 A

Page 1: ... WISI Communications GmbH Co KG www wisi de Mounting instruction OA 13 A ...

Page 2: ...le separated collection centres for metal parts waste in their own town An adequate separated collection for sending of the appliance to recycling treat ment and environmentally compatible disposal helps to avoid possible negative effects on the environment and on health thus favouring the reuse and recycle of the materials of which the appliance is made of The unauthorised disposal of the product...

Page 3: ...n 1 RL125 n 1 ACP125I n 1 TRP125 xx PAP CONTENTS OF THE PACKAGE Reflector Back bracket Arms and Feed Holder mount components ...

Page 4: ... CR n 1 M6x65 ISO 4017 UNI 5739 DIN933 n 2 VTC612I HR n 3 M6 ISO 10511 DIN 985 UNI7474 SIDE RODS OPTION Fix the side roads to the monopod A and turn them until they touch the edge of the reflector Drill bit size 7 the edge of the reflector corre sponding to the hole of the rod B Assemble with the screws supplied A B ...

Page 5: ...SEMBLING STEPS qAssembly of the pole clamp unit A fixing pole with a diameter from 75mm up to 90mm and thickness of 3mm is highly recom mended wAssembly of the antenna rear bracket to the pole clamp unit ...

Page 6: ...rrors roof pole perpendicularity for example The fine regu lation of the elevation pointing for optimized performances is left to the installer ASSEMBLING STEPS eAssembly of arms and feed holder assy rAssembly of the antenna reflector on the bracket assy Fine elevation pointing can be easily done us ing the threaded tie rod ...

Page 7: ...ean with a conventional duster the dish surface and the LNB feed do not use solvents for normal cleaning dry cleaning is normally enough use water or alcohol to remove solid attached elements dry with a cloth Paint If the painting has been ruined remove gently the rust if present using a fine abrasive paper type 00 then clean with acetone chloroform or similar oil free solvent dry and than repaint...

Page 8: ...Sihn Strasse 5 7 Inland Phone 49 7233 66 0 Fax 320 75223 Niefern Öschelbronn Export Phone 49 7233 66 280 Fax 320 Germany Email info wisi de n a r o f e l b a i l d l e h e b t o n n a c I S I W d e v r e s e r s n o i t a c i f i d o M l a c i n h c e T r o r r e g n i t n i r p y WISI Communications GmbH Co KG ...

Reviews: