14
You will need a 120 volt industrial heat gun available at most hardware stores.
DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
1. Follow steps 1-6 of the lighting with a handheld propane torch instruction.
2. Plug in and turn on heat gun to the high setting then insert heat gun.
3. Let heat gun run for 30 seconds.
4. Open the pellet feed door.
5. Ignition of the pellets will take approximately one minute. You will hear a “whoosh” when the pellets ignite.
6. Turn heat gun down to the low setting and continue to run until the stove reaches 400 degrees, this will
happen rapidly after ignition of the pellets.
7. Remove, turn off and store your heat gun.
8. Reinstall the primary chamber end slide.
OPEN
LIGHTING WITH A HEAT GUN
CONTROLLING THE TEMPERATURE
Because the damper slide is located behind the combustion
chamber, adjusting the temperature is the opposite of a
traditional wood stove.
To adjust the damper slide: turn handle counter clockwise one
half turn then slide to the desired position and retighten.
The open position will reduce the draft and slow the stove down
much like a crack in a drinking straw.
Closing the damper will increase higher temperatures and heat
output.
CAUTION: DO NOT OVER LOOSEN THE DAMPER
SLIDE HANDLE! THIS MAY CAUSE THE HANDLE
TO SEPARATE FROM THE DAMPER PLATE.
SHUTTING DOWN THE STOVE
When you are ready to shut your stove down simply close the
pellet feed door (move to the down position).
After you have closed the pellet feed door the stove will continue
to run for approximately 45 minutes.
When shutting down the stove make sure to close the draft slide
(holes blocked).