INS_TMC-GSFP[POE][M]   

08/12/19

   PAGE 6

INSTALLATION AND OPERATION MANUAL 

TMC-GSFP SERIES

FIGURE A

Dimensions are for a small size module

FIGURE B

Dimensions are for a standard one slot module

INSTALLATION CONSIDERATIONS 

This fiber-optic link is supplied as a Standalone/Rack module. Units should 

be installed in dry locations protected from extremes of temperature and 

humidity.

S

BP

-C14 

/ SBP-C03 

CARD CAGE RACKS

CAUTION:

 Although the units are hot-swappable and may be installed 

without turning power off to the rack, 

Hanwha 

recommends that the 

power supply be turned off and that the rack power supply is 

disconnected from any power source. Note: Remove electrical connector 

before installing in card cage rack.
1.  Make sure that the card is oriented right side up, and slide it into the

card guides in the rack until the edge connector at the back of the card

seats in the corresponding slot in the rack’s connector panel. Seating

may require thumb pressure on the top and bottom of the card’s front

panel.

CAUTION:

 Take care not to press on any of the LEDs.

2.  Tighten the two thumb screws on the card until the front panel of the

card is seated against the front of the rack.

WARNING: 

Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS:

 

A)  Elevated Operating Ambient - If installed in a closed or multi-unit rack

assembly, the operating ambient temperature of the rack environment

may be greater than room ambient. Therefore, consideration should

be given to installing the equipment in an environment compatible

with the maximum ambient temperature (Tma) specified by the

manufacturer.

B)  Reduced Air Flow - Installation of the equipment in a rack should be

such that the amount of air flow required for safe operation of the

equipment is not compromised.

.156 [3.96 mm]

.313 [7.95 mm]

Summary of Contents for TMC-GSFP Series

Page 1: ...egotiating is supported on the copper interface side These devices use either one or two optical fibers depending upon the selection of sold separately SFP optical modules A PoE model the TMC GSFPPOEM meets the IEEE802 3af IEE802 3at standard and provides up to 30 watts of PoE power The series also consists of a small size single channel model TMC GSFPM and a standard size single channel model TMC...

Page 2: ...MANUAL TMC GSFP Series CAT5e 6 BLACK BLACK WITH WHITE STRIPE Surface Mount Power 9 24 VDC 2 5 W max OR 24 VAC 2 5 W max FIGURE 1 TMC GSFPM SMALL SIZE UNIT FIGURE 2 TMC GSFPM SMALL SIZE UNIT REAR PANEL FRONT PANEL OPTICAL FIBER DETERMINED BY SELECTION OF SFP MODULE ...

Page 3: ...TMC GSFP Series CAT5e 6 IEEE802 3at 30W PoE BLACK BLACK WITH WHITE STRIPE or RED Surface Mount Power 48 57 VDC 35 W max FIGURE 3 TMC GSFPPOEM SMALL SIZE UNIT FIGURE 4 TMC GSFPPOEM SMALL SIZE UNIT REAR PANEL FRONT PANEL OPTICAL FIBER DETERMINED BY SELECTION OF SFP MODULE ...

Page 4: ...Series CAT5e 6 BLACK BLACK WITH WHITE STRIPE Surface Mount Power 9 24 VDC 2 5 W max OR 24 VAC 2 5 W max Rack power Supplied by Rack FIGURE 5 TMC GSFP STANDARD SIZE UNIT FIGURE 6 TMC GSFP STANDARD SIZE UNIT REAR PANEL FRONT PANEL OPTICAL FIBER DETERMINED BY SELECTION OF SFP MODULE ...

Page 5: ...ctions 100m 328ft Optical Fiber Determined By Selection Of SFP Module Ethernet IEEE 802 3 Network Element determined by user FIGURE 8 LED INDICATORS LINK COPPER POWER GREEN Solid No Activity Blinking Activity Solid No Activity Blinking Activity Unit powered up YELLOW Highest Data Rate OFF No Link No Link Unit powered down Position Resulting Data Rate OFF 1000FX requires use of Gigabit SFP module O...

Page 6: ... in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack WARNING Unit is to be used...

Reviews: