4_
English
INSTALLATION INSTRUCTIONS
1.
Select an installation position or place that can endure more than 4 times of the total weight
of the installation structure.
2.
At least 250mm or more of spare height is required above the
CEILING BOARD
.
3.
CEILING BOARD
’s thickness should be less than 40mm.
4.
Be sure to secure the SAFETY WIRE to avoid a product fall.
5.
If you want to attach the camera to the ADAPTOR, use the only provided SCREWS.
HOW TO INSTALL (XNP-6120/HCP-6120 SERIES)
1.
Place the
TEMPLATE
on the
CEILING BOARD
and drill a guided hole.
❶
Remove the round filling (“C”) from the
TEMPLATE
.
➋
Place
TEMPLATE
A onto the
CEILING BOARD
to which you will attach the ceiling
mount ADAPTOR and drill a hole of Ø213mm in diameter.
See the figure below for the hole shape.
More than 250mm
CEILING BOARD
Less than 40mm
213
213
TEMPLATE