Wise P620 Series Instruction Manual Download Page 6

1.3 Working Mechanism

     

NO

1

2

3

4

1) When a pressure is imposed both on the high side water pressure part and the low side water 

pressure part, the bellows will be shrunk by the sum of 2 differential pressures. 

Then, the rod connected to the bellows will move horizontally and the apparatus connected to 
the differential gauge indication part will rotate the caliber by the amount of displacement to
indicate the differential pressure value.

2) A bellows has a low side and a high side to create a certain displacement in combination with 

the spring according to the differential pressure range.

3) Three kinds of bellows are working whose thickness and appearance are differentiated by their 

differential pressure range. (0.11t, 0.15t, and 0.25t)

4) A spring is a device to create a certain differential pressure according to the differential pressure 

range and it has 12 kinds.

Name

Rod

Bellows

Housing

Spring

Remark

Function

 Transmit the bellows displacement to the differential pressure indication
 part.

 Separate the high side from the low side and make the displacement
 according to the water differential pressure.

 Protect the main water pressure part, providing it with a resistance
 force.

 Create a certain displacement according to the differential pressure
 range.

Rod

Bellows

Spring

Housing

High Side Water 

Pressure Part

Low Side Water 

Pressure Part

Summary of Contents for P620 Series

Page 1: ...Instruction Manual ITEM DIFFERENTIAL GAUGE MODEL P620 P630 SERIES ...

Page 2: ...ing destruction 4 Keep the working temperature range In excess of the working temperature range the measuring part may be damaged to destroy the surroundings 5 To detach the measuring instrument be sure to close the valve to block the measuring fluid Measuring fluid spillage may destroy the surroundings 6 When you are using oxygen for the measuring fluid rely on the Use No Oil manometer Any oil re...

Page 3: ...1 Generals 1 1 Spec and Size 1 2 Structure and Function 1 3 Working Mechanism 2 Use and Operation 2 1 Use 2 2 Operation 2 3 Standard Alphabetical Keypad Drawing CONTENTS ...

Page 4: ...age tanks Figure 1 shows the product appearance 1 1 Spec and Size 1 Indicating Instrument Size 100mm 150mm 2 Precision 1 5 or 1 0 of Full Scall 3 Max Working pressure P620 Series Max 50bar P630 Series Max 250bar 4 Liquid Contact Part Material Measuring Element 316SS Housing 316SS or MONEL 5 Connection Port Size NPT1 4 But to fix 3 way valves you may use PT1 2 and NPT 6 Standard Accessories 3 Way M...

Page 5: ...ne at the time of water pressure A measuring element is fixed to measure the pressure Discharge air in the pipe to the outside at the time of water pressure Attach a differential gauge to a measurement point 8 Attach fixing metal parts to the 2 pipe 5 Differential Gauge 3 316SS 3 Way Manifold Impulse Line 100 150mm U bolt Air Outlet Fixing Metal Part 7 Silver Coating Iron Housing Differential Gaug...

Page 6: ...tial pressure range 3 Three kinds of bellows are working whose thickness and appearance are differentiated by their differential pressure range 0 11t 0 15t and 0 25t 4 A spring is a device to create a certain differential pressure according to the differential pressure range and it has 12 kinds Name Rod Bellows Housing Spring Remark Function Transmit the bellows displacement to the differential pr...

Page 7: ...During water level checking set the lower part to the high side and the upper part to the low side for the pressurizing tank but connect the lower part to the high side and open the low side to the atmosphere for the open tank for atmosphere 4 In case of corrosive fluid you must choose anticorrosive diaphragm or side diaphragm 5 In case you choose a side diaphragm and its high side and low side ar...

Page 8: ...e the pipe or differential gauge housing is fully discharged The air normally creates an differential gauge indication error 4 Next open the low side valve close the equalizing valve and check if the indicating instrument reading is normal before main operation 5 If you want to remove a differential gauge from the tube due to its trip open the equalizing valve close the low side valve and close th...

Page 9: ...2 3 Standard Alphabetical Keypad Drawing ...