4. Specifications
Detectors GT-1010
GX-1010
GT(X)-1010D
Measuring Gas
Measuring Range
Detection Principle
Sensor type
Sampling
Local Calibration
Power
Power Consumption
Output Signal
Load Impedance
Explosion Proof
Detector Housing
Sensor Housing
Wiring Connection
Cable
Response Time
Zero/Span Drift
Expected Life
Temperature Range
Humidity Range
Flammable Gas
0 ~ 100% LEL
Catalytic combustion
Integrated
Diffusion or Suction
Yes
18 to 30 VDC
100 mA
DC 4-20mA
600
Ω
Ex d IIC T6
Aluminium Diecasting
SUS 316L
PF 3/4” (PT, NPT
available)
3 wire shielded
< 20 secs at T90
+/-3% offset / month
36 to 60 month
-30 to 50 ºC
Below 95% R.H.
Toxic Gas
Depending on the
GasElectrochemical
Integrated
Diffusion or Suction
Yes
18 to 30 VDC
25 mA
DC 4-20mA
250
Ω
Ex d IIC T6
Aluminium Diecasting
SUS 316L
PF 3/4” (PT, NPT
available)
2 wire shielded
Depending on the sensor
+/-3% offset / month
12 to 48 month
-25 to 55 ºC
Below 95% R.H.
Flammable / Toxic Gas
0 ~ 100% LEL /
Depending on the
GasCatalytic /
Electrochemical
Remote (up to 15M)
Diffusion or Suction
Yes
18 to 30 VDC
100 / 25 mA
DC 4-20mA
250
Ω
Ex d IIC T6
Aluminium Diecasting
SUS 316L
PF 3/4”
(PT, NPT available)
2 wire shielded
Depending on the sensor
+/-3% offset / month
12 to 48 month
-25 to 55 ºC
Below 95% R.H.