3) HIGH & LOW ALARM

As a dual set point, this provides the combination of two independent single set
points metioned above.

4) HIGH & HIHIGH ALARM

As a dual set point, this provides the combination of two independent High alarm 
set points.

5) LOW & LOLOW ALARM

As a dual set point, this provides the combination of two independent Low alarm
set points.

설정치

0

최대압력

4

1

5

2

6

3

(CONNECTION BOX)

(MICRO SWITCH)

연결단자 

,

(SET POINT)

(MAX.PRESSURE)

단자대

마이크로 스위치

(CONNECTION TERMINAL)

2

3

0

4

1

5

2

6

3

상한접점 (검정색침), 연결단자 

1 , 2

하한접점 (적색침), 연결단자 

6

5 ,

설정치

최대압력

(SET POINT)

(MAX.PRESSURE)

(CONNECTION BOX)

단자대

(MICRO SWITCH)

마이크로 스위치

(HIGH CONTACT (BLACK POINTER),

(LOW CONTACT (RED POINTER),

 CONNECTION TERMINAL) 

CONNECTION TERMINAL)

0

4

1

5

2

6

3

상한접점 (검정색침), 연결단자 

1 , 2

상한접점 (적색침), 연결단자 

5

4 ,

설정치

최대압력

(SET POINT)

(MAX.PRESSURE)

(CONNECTION BOX)

단자대

(MICRO SWITCH)

마이크로 스위치

(HIHIGH CONTACT (BLACK POINTER),

(HIGH CONTACT (RED POINTER),

 CONNECTION TERMINAL) 

CONNECTION TERMINAL)

0

4

1

5

2

6

3

하한접점 (검정색침), 연결단자 

2 , 3

하한접점 (적색침), 연결단자 

6

5 ,

설정치

최대압력

(SET POINT)

(MAX.PRESSURE)

(CONNECTION BOX)

단자대

(MICRO SWITCH)

마이크로 스위치

(LOW CONTACT (BLACK POINTER),

(LOLOW CONTACT (RED POINTER),

 CONNECTION TERMINAL) 

CONNECTION TERMINAL)

Summary of Contents for 531 Series

Page 1: ...USER MANUAL MODEL P510 P520 531SERIES ITEM ELECTRIC CONTACTS TYPE PRESSURE GAUGE ...

Page 2: ...ore removing This will prevent the fluid or other substances to release This release might cause the destruciton of surroundings 6 Use Use No Oil Pressure gauges for the environment where Hydrocarbon or Oxygen is present General Pressure gauges with the left over oil inside can lead to explosion when it gets mixed with oxygen or Hydrocarbon 7 When installing the product please follow the instrucit...

Page 3: ...ICATIONS 3 FEATURES 4 SPECIFICATION AND STANDARDS 5 STRUCTURE AND FUNCTION 6 OPERATING PRINCIPLE 7 CONTACT POINT WORKING TYPE AND CONNECTION 8 HOW TO SET 9 MAINTENANCE AND OPERATION 10 USE 11 INSTALLATION 12 WIRING CONTENTS ...

Page 4: ...the switch is mounted 3 A contact switch pressure indicating has separate indicator and setting scales for easier setting 4 Specification and Standards 1 Norminal diameter 100 and 160mm 2 Accuracy Indication range 1 0 of Full Scale Alarm setting 1 0 of Full Scale 3 Materials of wetted part Stainless Steel 4 Connection type 3 8 1 2 PT NPT PF 5 Number of contacts 1 X SPDT or 2 X SPDT 6 Working tempe...

Page 5: ...es 5 Structure and Function Setpoint Adjustment Dial Cap Terminal Box Indicator Process Connection NO 2 Setting Pointer NO 2 Setpoint Indicator Scale Plate NO Description Remark NO 1 Setting Pointer NO 1 Setpoint Indicator ...

Page 6: ...4mm and its principle is to point currently applied pressure by using a turn angle 270º Therefore Bourdon Tube and Movement are the most important and these parts must be well assembled in the pressure gauge because these parts leads to precise machining accurracy 7 Contact Point Working Type and Connection 1 HIGH ALARM As a Single Contact when the pressure reaches higher than its set point User c...

Page 7: ...2 3 0 4 1 5 2 6 3 상한접점 검정색침 연결단자 1 2 하한접점 적색침 연결단자 6 5 설정치 최대압력 SET POINT MAX PRESSURE CONNECTION BOX 단자대 MICRO SWITCH 마이크로 스위치 HIGH CONTACT BLACK POINTER LOW CONTACT RED POINTER CONNECTION TERMINAL CONNECTION TERMINAL 0 4 1 5 2 6 3 상한접점 검정색침 연결단자 1 2 상한접점 적색침 연결단자 5 4 설정치 최대압력 SET POINT MAX PRESSURE CONNECTION BOX 단자대 MICRO SWITCH 마이크로 스위치 HIHIGH CONTACT BLACK POINTER HIGH CONTACT RED POINTER CON...

Page 8: ...wice in 6 months to check contact operation 7 If the indication instrument makes a big error remove it from the product for inspection It may have been caused by wear corrosion external shock vibration or shock of a part In this case you must remove adjust or exchange the part 8 The standard rated current shall follow 4 7 but it may be different when the product is equipped with a special micro so...

Page 9: ... 11 Installation 1 Install in a place devoid of moisture vibration dust or corrosive gas 2 Avoid areas that might exceed the temperature ranges specified in this manual 3 Make sure to protect from lightning or steam 4 Avoid areas with direct sun light 5 Use M5 nuts and bolts to mount on a panel or wall using the mounting holes If mounting brackets are used make sure it is installed securely 6 Inle...

Reviews: