1
Date
Code Number:
Series
Model number
Draft
TVLink RS868
T387.01
21-09-09
TVRRL868A02PMR
DIGITAL RADIO CONTROL SYSTEM TVRRL868A02P
EN
ATTENTION!
The subject appliance must be installed only by qualified technical
personnel in compliance with the standards. All connections must be
rated for a single-phase power supply of 230V. For the disconnection from
the power line, use an all-pole switch with contact with an opening of at
least 3,5mm. Only suitable materials for the connections must be used to
guarantee insulation that complies with current standards on the subject
of electrical safety. The programmer carries out movement commands by
radio; all the necessary safety devices are to be seen to separately.
The device’s signal reception could be disturbed by several factors such as:
- the presence of electrical frequency noise being transmitted by other
appliances working in the same environment and on the same frequency.
- appliances installed in containers with metal parts; only use containers made
of plastic.
1- GENERAL DESCRIPTION
Receiver for the remote control of appliances up to a maximum resistive
power of 1000 W with ON/OFF or impulsive function and compatible with the
TVLink system.
The commands which are sent by transmitter can be:
- single (every channel activates and deactivates the load, ON/OFF or
impulsive)
- in pairs:
Channel pair 1,2: channel 1- ON and channel 2 OFF
Channel pair 3,4: channel 3- ON and channel 4 OFF
Channel pair 6,7: channel 6- ON and channel 7 OFF
The specific TVLINK codes are encoded directly by the manufacturer inside
an EEprom memory module that maintains the information even in case of
blackouts. They are also printed on the product label so they can be inserted into
the TVLINK device. These codes cannot be cancelled or modified as they are an
integral part of the receiver.
The standard radio control codes can be inserted (memorized) or cancelled in
the receiver by pressing a button through a small hole located to one side of the
aerial (see picture 1)
The code transmission type is “Rolling-code”. The code is changed for every
transmission through the use of an algorithm that only the receiver is able to
recognize.
The maximum number of memorisations that can be executed is 42.
1.1- How to modify the function of the receiver (ON/OFF, impulsive)
In order to modify the function of the receiver from ON/OFF to impulsive (and
vice-versa), it is necessary to carry out the following procedure:
1) switch off the power supply of the receiver
2) push and keep pushed the internal push-button P1, switch on the power
supply (the buzzer will emit a continuous sound). After 5 seconds, an
intermittent sound will indicate that the function of the receiver has been
changed.
2- Transmitters
The transmitters are encoded in the factory and each transmitter has its own
unique code.
Caution! If you keep a channel button pressed down for more than 30 seconds
the transmitter will automatically switch off.
The receiver is compatible with all transmitters of the TVLink range: TVTXV,
TVTXP, TVTXC, TVTXK, TVTXQ, TVTXL, TVTXS, TVTXW, TVTXM.
3- ATTENTION: The first transmitter can only be memorized using
the receiver (you are advised to cancel the entire memory content at the
beginning of each installation by pressing the P1 button).
3.1- Memorisation single channel
The channels ch1,ch2,ch3,ch4... will be memorised one by one.
1- Press and hold down the pushbutton P1 of the receiver, the buzzer will sound
continuously.
2- Transmit the channel which is to be memorised, once the channel is
memorised, the buzzer will sound intermittently, release the pushbutton.
Repeat points 1 and 2 to memorise ulterior channels from receiver.
See paragraph 4 to memorise ulterior channels from transmitter.
3.2- Memorisation couple of channel
s
The channels ch1,ch2 and ch3,ch4 and ch6,ch7 will be memorised in couple.
1- Press
two times
and hold down the pushbutton P1 of the receiver, the buzzer
will sound continuously.
2- Transmit one of the couple of channel which is to be memorised, once
the channel is memorised, the buzzer will sound intermittently, release the
pushbutton.
Repeat points 1 and 2 to memorise ulterior channels from receiver.
See paragraph 4 to memorise ulterior channels from transmitter.
Wise House, 21 Lydden Road, Wandsworth, London, SW18 4LT
Telephone: 020 8874 2234
Fax: 020 8871 2262
www.wisecontrols.com
WISE
CONTROLS
4- How to insert a transmitter via radio without having to access the
receiver by means of an already memorized transmitter (memory indexing
procedure)
The type of memorisation of the channels (single, couple) depends on how the
channel, whitch is used in point 2, has been memorized.
1) Press the button P3 located inside the already memorized transmitter. The
enabled receiver sound continuously for 5 seconds.
2) Transmit a channel present in the memory of the receiver, in which the new
code is to be memorized, within 5 seconds and the buzzer will interrupt the
sound for 1 sec, and then carry on for another 5 seconds.
3) Transmit the new channel to be memorized within 5 seconds and once
memorized the buzzer will sound intermittently.
To insert other transmitters another code repeat operations 1,2 and 3
If the receiver’s memory is full it cannot be enabled and this will be indicated
by the buzzer B1 sounding intermittently.
5- To cancel a code from the receiver:
1) press three times and then hold down the button P1 and the buzzer will sound
intermittently and slowly.
2) press the channel which is to be cancelled, once it had been cancelled the
buzzer will sound continuously. In the case, the channel has been memorized in
pairs, this operation cancels both channels.
5.1- To cancel a code from via radio:
1) press three times and then hold down the button P3 within 5 seconds and the
buzzer will sound intermittently and slowly.
2) press the channel which is to be cancelled, once it had been cancelled the
buzzer will sound continuously. In the case the channel has been memorized in
pairs, this operation cancels both channels.
5.2- To cancel all codes in memory:
1) press the button P1 four times and hold down for at least 10 seconds (during
this period the buzzer will sound intermittently and rapidly) until the buzzer will
sound continuously. Release the button.
6- Full or empty memory
If the memory of the receiver is full or empty, the buzzer will make 3 bip both
during the memorisation and after the reset of the receiver.
6.1- Errors during the memorising or deleting
If the code hasn’t been memorised it could be due to the following reasons:
- the memory is full. In this case the buzzer will sound intermittently and slowly
for 3 seconds each time it is switched on,
- the indexing procedure has not been correctly started up,
- the code already exists in memory.
If the code hasn’t been cancelled it could be due to the following reasons:
- the code doesn’t exist in memory.
7- TECHNICAL SPECIFICATIONS
Reception frequency
868.3 MHz
Intermediate frequency
10.7MHz
Sensitivity (finely tuned signal)
1 µV
Power supply
230 Vac
Consumption
0.5W
Maximum commutable power at the relay:
with resistive load
8A 250 Vac
8A 30 Vdc
Operating temperature range
-20° ÷ + 60 °C
In the view of a constant development of their products, the manufacturer
reserves the right for changing technical data and features without prior notice.