WUSB Module User Guide R 0.1 

Page 14 

 

 Wisair Wireless USB  

 

6  Testing Procedure  

The following is a basic testing procedure to demonstrate OFDM signal transmission from 
the Host side module in TFI mode. 

1.

 

Connect the Host module to the PC USB port. Wait approximately 30 seconds for 
hardware initialization to complete. 

2.

 

Double click the WisMan 

 shortcut icon on the PC desktop to initiate the WisMan 

application. 

 

Figure 7: Initial screen 

3.

 

In the WisMan initial screen, select 

Devices > Open >Intrusive 

to open the Intrusive 

mode tabs of the configuration screens.  

 

Figure 8: Radio Test Mode tab 

4.

 

Select the 

RadioTest Mode

 tab and press the 

OFDM TFC1 

button. 

5.

 

Wait for the green signal to in. 

Summary of Contents for WSR601

Page 1: ...Certified Wireless USB Module User Guide Preliminary...

Page 2: ...ion visit www wisair com Wisair 2007 All rights reserved All right title and interest copyrights patents know how trade secrets and other intellectual property relating to this publication and to Wisa...

Page 3: ...d Firmware Version 11 4 Technical Specifications 12 5 FCC Statements 13 6 Testing Procedure 14 Table of Figures Figure 1 PC to PC communication via WiMedia based application 4 Figure 2 PC to PC Periph...

Page 4: ...ng the right balance between functionality and aesthetics It allows remote content browsing sharing control multi channel streaming hotsync printing fast copy and very fast information exchange betwee...

Page 5: ...res Single port USB 2 0 1 1 CWUSB Host or Device Wire Adapter functionality with advanced throughput Support for Cable Association Cable association functionality is provided by the reference design 1...

Page 6: ...contains a previous HWA DWA driver installation please perform a proper uninstall procedure using the Control Panel Add or Remove Programs utility 1 Ensure that the Host module is detached from the PC...

Page 7: ...e 7 4 Click Next a secondary screen displays 5 Click Continue Anyway Repeat as many times as the request displays four times in total 6 The following notice is displayed click OK to proceed 7 The fina...

Page 8: ...ng the Found New Hardware Wizard 9 Select No not this time and click Next 10 Select Install the software automatically recommended and click Next to install the first driver 11 The Hardware Installati...

Page 9: ...ful 17 Connect the Host module to the PC after restart 18 In order to verify a successful installation run the Windows Device Manager utility Start Run devmgmt msc and verify that it recognizes the Ho...

Page 10: ...ch and reinsert the dongle to restart the module 3 2 Troubleshooting 3 2 1 Verifying Driver Installation To check for proper installation of drivers In order to verify a successful installation run th...

Page 11: ...Reading Software and Firmware Version In order to ensure that you are working with the latest version of software and hardware you can check the versions of each component as follows Wisair applicatio...

Page 12: ...points types Bulk in out Interrupt Control USB association type Cable association Proprietary preset at production PCB size approx 18mm x 50mm Antenna 1 micro SMT antenna connector 1 onboard antenna s...

Page 13: ...nclude but are not limited to AM FM commercial broadcast television cellular services radar air traffic control pager and personal communications services PCS These licensed services along with uninte...

Page 14: ...ort Wait approximately 30 seconds for hardware initialization to complete 2 Double click the WisMan shortcut icon on the PC desktop to initiate the WisMan application Figure 7 Initial screen 3 In the...

Page 15: ...5 Figure 9 WisMan Radio Test Mode tab Note If the USB dongle is not recognized by the PC or the WisMan utility you can do the following Restart the dongle by detaching from the PC and reinserting the...

Reviews: