05

06

feeling for more

Pump runs 
all the time

1. Installation is not horizontal

2. There is sludge inside tank

Problem                    Cause                                          Action                      

Pump makes
loud noise

Pump can’t 
start working

Adjust the tank make it level

Clean the inside of tank and probe surface

1. The water is siphoning back 
    in the pump

Check whether the outlet pipe is lower than 
pump thus result in siphoning,  please raise the 
condensate pump position

1. Installation is not horizontal

2. The power can’t reach pump

3. The voltage isn’t correct

1. Adjust the tank, check water level

2. Check power supply

3. Check the voltage

7. Troubleshooting

6.4 Connect power supply;

6.5 After the system is properly connected, ensure that the pump is powered on, 

      run the air conditioner and observe whether the pump is working normally. If 

      the pump does not work properly, please contact a professional for repair.

     (As shown below)

feeling for more

6.6 The condensate pump is built in working indicator lamp, and the green light 

     on the front cover is on when working, and the alarm buzzer will emit a

      " drip .... drip" sound when the pump fails to drain water.

Work indicator

Note:  Proper  use  and  maintenance  can  improve  the  life  of  pump.  We  suggest  to 

check and clean the condensate pump before seasons changing or next year using.

Reviews: