OPERATION MANUAL
feeling for more
Silence Running,Reliable And Durable
P18/P36
CONDENSATE PUMP
Page 1: ...OPERATION MANUAL feeling for more Silence Running Reliable And Durable P18 P36 CONDENSATE PUMP ...
Page 2: ...00V 230V 50 60Hz 10m 36L h 9 6GPH 150ml 0 50 45000btu hr 21dB A P36 12 10 8 7 6 2 0 5 10 15 20 25 30 35 40 P36 P18 4 Flow Rate Chart P16 P36 0m 24 40 2m 20 36 4m 18 26 6m 16 22 8m 12 18 10m 8 14 3 Technical Data Model Voltage Discharge head Max Flow rate Max Tank capacity Mini splits up to Sound level at 1m Ambient temp Model Performance l h head Meters head m Flow L h 19dB A 18L h 4 8GPH 30000btu...
Page 3: ...ause the condensate pump fail to discharge water in time leading to water leakage 7 The condensate pump has a built in buzzer When the buzzer sounds all the time please turn off the air conditioner and ask a professional to repair it 5 Safety Instructions 1 Place the tank horizontal when installing do not tilt the pump Check whether the level drop is centered if there is tilt adjust the water leve...
Page 4: ...water level 2 Check power supply 3 Check the voltage 7 Troubleshooting 6 4 Connect power supply 6 5 After the system is properly connected ensure that the pump is powered on run the air conditioner and observe whether the pump is working normally If the pump does not work properly please contact a professional for repair As shown below feeling for more 6 6 The condensate pump is built in working i...