Safety Instructions 

Thanks for buying our products!
Please read the manual carefully before use. It will help you greatly in installation 
and  use.  Please  attach  the  manual  when  selling  the  products  so  that  the  end 
users can refer to the usage and cautions.

1. Place the tank horizontal when installing, do not tilt the pump. Check whether  
    the  level drop is centered; if there is tilt, adjust the water level before using it.

2. Do not place electrical appliances or valuables under the condensate pump 
    to avoid loss caused by power failure or water leakage.

3. Non - professional personnel should not install it to avoid danger.

4. The condensate pump is not waterproof. Do not place it in the open air, 
     outdoors or in a place prone to flooding.

5. The condensate pump power supply needs to be independent to maintain 
    permanent power supply. For details of connecting with air conditioning 
    system, please refer to the wiring diagram.

6. It is prohibited that the water inflow is bigger than our stated flow rate, which 
    will easily cause the motor to work continuously and fail. Instant big water 
    inflow will also cause the condensate pump fail to discharge water in time, 
    leading to water leakage.

Summary of Contents for P16

Page 1: ...OPERATION MANUAL feeling for more WENLING WIPCOOL REFRIGERATION EQUIPMENT CO LTD Website www wipcool com feeling for more Reliable And Durable Silence Running P16 P32 CONDENSATE PUMP ...

Page 2: ...e condensate pump to avoid loss caused by power failure or water leakage 3 Non professional personnel should not install it to avoid danger 4 The condensate pump is not waterproof Do not place it in the open air outdoors or in a place prone to flooding 5 The condensate pump power supply needs to be independent to maintain permanent power supply For details of connecting with air conditioning syste...

Page 3: ...7 53 16 7 7 12 17 85 6 48 3 40 No 1 2 3 4 No 5 6 7 8 No 9 10 11 Part Name Water inlet pipe Tank Filter net Upper cover Part Name Upper cover plate Air hole φ6x20 Water pipe φ6x1500 Induction signal line Part Name Power cord Water outlet pipe Condensate pump assembly 2 Dimension 3 Technical Data Model Voltage Discharge head Max Flow rate Max Tank capacity Mini splits up to Sound level at 1m Ambient...

Page 4: ...re the tank is placed smoothly and the outlet pipe of the air conditioner is tightly connected with the water pipe of tank as shown below 3 Connect the vent pipe with the air hole as shown below 4 Place the pump in the position beyond the ceiling as shown below 5 The use of shockproof materials ensure the water tank and condensate pump stuck firmly low vibration to avoid noise 6 Pay attention to t...

Page 5: ...to the water outlet tie the water pipe make sure that the discharge head is less than 8m and the length of the water pipe is less than 25m as shown below 9 The condensate pump is equipped with a signal indicating light When the pump is working and draining normally the green light is on When the water level is in alarm the red light is on as shown below 2M 10 Power supply wiring in order to avoid ...

Page 6: ...tion is not horizontal 2 There is sludge inside tank 1 A B C WARNING Problem Cause Action Pump makes loud noise Pump can t start working Adjust the tank make it level Clean the inside of tank and probe surface 1 The water is siphoning back in the pump Check whether the outlet pipe is lower than pump thus result in siphoning raise the condensate pump position 1 Installation is not horizontal 2 The ...

Reviews: